Accessories

Image Part Number Description / PDF Quantity Rfq
4112691

4112691

Fluke Electronics

GOLDCAREPLAN-GROUP1-5YR

0

OC4USB

OC4USB

Fluke Electronics

CABLE OPTICAL SCOPEMETER USB

3

C345

C345

Fluke Electronics

CARRYING CASE SOFT

0

4112976

4112976

Fluke Electronics

GOLDCAREPLAN-GROUP6-1-7YR

0

ES-162P4-2

ES-162P4-2

Fluke Electronics

EARTH GROUND STAKE SET FOR 4 POL

0

FLK-CNX C3001

FLK-CNX C3001

Fluke Electronics

MODULE SOFT CASE

0

4112929

4112929

Fluke Electronics

GOLDCAREPLAN-GROUP5-4YR

0

CXT80

CXT80

Fluke Electronics

CASE PELICAN HARD 80/180 SERIES

0

SCC290

SCC290

Fluke Electronics

CARRYING CASE KIT FOR SOFTWARE

0

FVF-BASIC

FVF-BASIC

Fluke Electronics

FLUKEVIEW FORMS W/CABLE

3

80AK-A

80AK-A

Fluke Electronics

ADAPTER THERMOCOUPLE TYPE K

23

BP7235

BP7235

Fluke Electronics

NIMH BATTERY PACK

3

CT-53

CT-53

Fluke Electronics

1 X CLAMP SENSOR, 1 X USER MANUA

0

EI-1625

EI-1625

Fluke Electronics

CLAMP SET SELECTIVE/STAKELESS

0

4112738

4112738

Fluke Electronics

GOLDCAREPLAN-GROUP2-3YR

0

4112678

4112678

Fluke Electronics

GOLDCAREPLAN-GROUP1-3YR

0

RS500

RS500

Fluke Electronics

PROBE REPLACEMENT SET

0

C173X

C173X

Fluke Electronics

SOFT CASE FLUKE-173X

0

2609

2609

Fluke Electronics

CASE LONG PROBE CARRYING

0

MP1-MAGNET PROBE 1

MP1-MAGNET PROBE 1

Fluke Electronics

MAGNET PROBES FOR 4MM BANANA SET

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top