Accessories

Image Part Number Description / PDF Quantity Rfq
TAS90

TAS90

Fluke Electronics

SHIELDED TEST LEAD ACC. SET

0

4112745

4112745

Fluke Electronics

GOLDCAREPLAN-GROUP2-4YR

0

2629

2629

Fluke Electronics

CABLE 50 FT. EXTENSION 1620-X

0

4112983

4112983

Fluke Electronics

GOLDCAREPLAN-GROUP6-2-7YR

0

H6

H6

Fluke Electronics

HOLSTER INFRARED THERMOMETER

0

4112777

4112777

Fluke Electronics

SILVERCAREPLAN-GROUP2-4YR

0

BP120MH

BP120MH

Fluke Electronics

RECHARGEABLE BATTERY PACK

5

CT-500

CT-500

Fluke Electronics

1 X CLAMP SENSOR, 1 X USER MANUA

0

7109-2013-1

7109-2013-1

Fluke Electronics

TRANSPORT COVER

0

H900

H900

Fluke Electronics

HOLDER TEST LEAD WIRES 8MM DIA

1

DR80

DR80

Fluke Electronics

METER DISPLAY UPGRADE 80 SERIES

1

7109-2027

7109-2027

Fluke Electronics

ADJUSTABLE PROBE HOLDING FIXTURE

0

9308

9308

Fluke Electronics

CASE HARD CARRYING

0

80TK

80TK

Fluke Electronics

MODULE THERMOCOUPLE

3

700G/TRACK

700G/TRACK

Fluke Electronics

DATA LOGGING CABLE & SOFTWARE

0

4112853

4112853

Fluke Electronics

GOLDCAREPLAN-GROUP4-3YR

0

SCC120E

SCC120E

Fluke Electronics

CABLE CARRYING AND SOFTWARE KIT

0

810SC-20

810SC-20

Fluke Electronics

SENSOR CABLE 20 FT

0

FLK-TI-BLUETOOTH

FLK-TI-BLUETOOTH

Fluke Electronics

BLUETOOTH HEADSET

0

C510

C510

Fluke Electronics

METER CASE LEATHER W/BELT LOOP

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top