Accessories

Image Part Number Description / PDF Quantity Rfq
M1028

M1028

Comet America

B2GINPUT MOD,MS LOGGER 0-5A

20

M1015

M1015

Comet America

E2 INPUT 0-10V, ISOLATED

20

M1020

M1020

Comet America

K1 MOD. FOR MS RTD SENSOR PT1000

20

K0945

K0945

Comet America

CONNECTION ADAPTER FOR LOGGERS

20

M1026

M1026

Comet America

B0 INPUT MOD,MS LOGGER 0-20MA

20

M1024

M1024

Comet America

Q INPUT MODULE FOR DATALOGGER MS

20

M1023

M1023

Comet America

P INPUT MODULE FOR DATALOGGER MS

20

MLP008

MLP008

Comet America

MULTILOGGER HOLDER FOR DIN

20

G9000

G9000

Comet America

WIRELESS ALARM G0841W

20

MP013

MP013

Comet America

UNIVERSAL HOLDERS FOR LOGGER

20

MP024

MP024

Comet America

INTERFACE FOR SEND, RECEVING SMS

20

LP102

LP102

Comet America

MAGNETIC HOLDER DATALOGGER "U"

20

MP049

MP049

Comet America

MS55D LOGGER IP54 CASE

20

BM511

BM511

Comet America

PLASTIC CASE FOR MULTILOGGER

20

M1061

M1061

Comet America

RP INPUT MODULE FOR LOGGER MS

20

M1001

M1001

Comet America

A0 INPUT MOD,MS LOGGER 4-20MA

20

M1035

M1035

Comet America

KG MOD.FOR MS RTD SENSOR PT100

20

M1029

M1029

Comet America

D0G INPUT 0-100MV, ISOLATED

20

M1031

M1031

Comet America

D2G INPUT 0-10V, ISOLATED

20

M1021

M1021

Comet America

N INPUT MODULE FOR DATALOGGER MS

20

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email