Accessories

Image Part Number Description / PDF Quantity Rfq
PPA03V100

PPA03V100

Bartovation

PERACETIC ACID TEST STRIPS, 0-16

100

J0114R

J0114R

Bartovation

UNIVERSAL 1-14 PH TEST PAPER ROL

100

PQT02B100

PQT02B100

Bartovation

RESTAURANT QUATERNARY AMMONIUM (

100

PQT04V50

PQT04V50

Bartovation

VERY HIGH LEVEL QUAT STRIPS 0-10

100

PPH06B50

PPH06B50

Bartovation

SHORT RANGE 0.0-6.0 PH RANGE LIT

100

PPA01V100

PPA01V100

Bartovation

PERACETIC ACID TEST STRIPS, 0-50

100

PQT06V100

PQT06V100

Bartovation

100 2" PAPER QUAT QAC (QUATERNAR

100

PWQ09V50

PWQ09V50

Bartovation

PHOSPHOROUS AND PHOSPHATE DETECT

100

PCL08V100

PCL08V100

Bartovation

RESTAURANT SANITIZER CHLORINE TE

100

PWQ10V50

PWQ10V50

Bartovation

FREE SULFITE TEST STRIPS, 10-500

100

0555R

0555R

Bartovation

PH TEST PAPER FOR KOMBUCHA BREWI

100

PGA2020

PGA2020

Bartovation

20" X 20" REUSABLE COBALT CHLORI

100

MCL08R

MCL08R

Bartovation

RESTAURANT SANITIZER CHLORINE TE

100

PSP02V100

PSP02V100

Bartovation

METHYL VIOLET TEST PAPER NO COL

100

PCL09V100

PCL09V100

Bartovation

RESTAURANT SANITIZER IODINE TEST

100

PSP01P50

PSP01P50

Bartovation

GRADE 1 CRISP SEPARATION CHROMAT

100

PWQ11V100

PWQ11V100

Bartovation

USA MADE TOTAL WATER HARDNESS TE

100

PCL05V100

PCL05V100

Bartovation

FREE CHLORINE/BLEACH TEST STRIPS

100

PSP04B40

PSP04B40

Bartovation

SCIENTIFIC GLUCOSE TEST PAPER ST

100

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email