Accessories

Image Part Number Description / PDF Quantity Rfq
PGA01V100

PGA01V100

Bartovation

COBALT CHLORIDE MOISTURE AND HUM

99

PSP01V100

PSP01V100

Bartovation

LEAD ACETATE TEST PAPER FOR DET

100

PGE02V100

PGE02V100

Bartovation

CONTROL (NO CHEMICAL) GENETIC TA

100

PCL06V100

PCL06V100

Bartovation

ACTIVE CHLORINE/BLEACH TEST STRI

100

PPX03V100

PPX03V100

Bartovation

PEROXIDE TEST STRIPS, 0-400 PPM

100

PCD01V50

PCD01V50

Bartovation

CHLORINE DIOXIDE SINGLE FACTOR T

100

MQ400R

MQ400R

Bartovation

RESTAURANT QUATERNARY AMMONIUM (

100

LPH4710K30

LPH4710K30

Bartovation

30 PACK PH BUFFER CALIBRATION SO

100

PQT01V100

PQT01V100

Bartovation

LOW LEVEL RESIDUAL QUATERNARY AM

100

PGE99K

PGE99K

Bartovation

SUPER TASTER TEST LAB KIT WITH I

100

PPH01V100

PPH01V100

Bartovation

PH 1-14 WIDE RANGE TEST STRIPS [

100

PGA04C20

PGA04C20

Bartovation

REUSABLE BTB AMMONIA LEAK DETECT

100

PLI99K

PLI99K

Bartovation

RED & BLUE LITMUS PAPER ACID/BAS

100

PSS01V25

PSS01V25

Bartovation

AMMONIA TEST STRIPS 0-100 PPM [V

100

PSP03V100

PSP03V100

Bartovation

PHENOLPHTHALEIN TEST PAPER [VIAL

100

PSS03V50

PSS03V50

Bartovation

MOLYBDATE TEST STRIP 0-350+ PPM

98

PLI07V100

PLI07V100

Bartovation

CONGO RED TEST PAPER [VIAL OF 10

100

PQT03V50

PQT03V50

Bartovation

QUATERNARY AMMONIUM (QAC, MULTI

100

PQT05V100

PQT05V100

Bartovation

RESTAURANT QUATERNARY AMMONIUM (

100

PCD02V50

PCD02V50

Bartovation

CHLORINE DIOXIDE SINGLE FACTOR T

100

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top