Accessories

Image Part Number Description / PDF Quantity Rfq
MDL001

MDL001

B&K Precision

MAINFRAME

0

TLPWR1

TLPWR1

B&K Precision

HC TEST LEAD SET 60A 2M SPD CONN

14

DRRM3U1

DRRM3U1

B&K Precision

RACKMNT KIT FOR ONE 3U INSTRUMEN

0

AK57X

AK57X

B&K Precision

INTERFACE SOFTWARE W/USB DONGLE

0

TL983P-KIT

TL983P-KIT

B&K Precision

3-PHASE KIT

3

AK40G

AK40G

B&K Precision

USB TO GPIB ADAPTER

8

SASPVS

SASPVS

B&K Precision

SOLAR ARRAY SIM SOFTWARE

2

USB2RS

USB2RS

B&K Precision

USB TO SERIAL (RS232) ADAPTER

7

TL89T1

TL89T1

B&K Precision

TRANSFORMER TEST FIXTURE FOR 894

1

IT-E151

IT-E151

B&K Precision

RACK MOUNT KIT FOR 1785B - 1788

45

LC 33

LC 33

B&K Precision

CARRY CASE FOR 300 SERIES DMM

0

XLN485

XLN485

B&K Precision

RS485 CABLE

0

RKPVS

RKPVS

B&K Precision

PVS RACKMOUNT KIT

1

RK3U

RK3U

B&K Precision

RACKMOUNT KIT FOR 9832 AND 9833

2

MDL002

MDL002

B&K Precision

MAINFRAME EXTENSION

2

PR262

PR262

B&K Precision

EMC NEAR-FIELD PROBES

4

TL8KC1

TL8KC1

B&K Precision

SHIELDED FOUR-TERM KELVIN CLIP T

12

TLKB1

TLKB1

B&K Precision

4-WIRE KELVIN CLIP TEST FIXTURE

0

TLBB53

TLBB53

B&K Precision

POWER CORD BREAKOUT BOX

3

RK153

RK153

B&K Precision

BRACKETED RACK MOUNT KIT (FOR MD

13

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments