Accessories

Image Part Number Description / PDF Quantity Rfq
SP270

SP270

B&K Precision

CURR CLAMP 2000A AC 1MV/A

0

AK IR

AK IR

B&K Precision

RS232C TO IR ADAPTER

0

SP221

SP221

B&K Precision

CURR CLAMP 100A AC 100 MV/A

0

902408000

902408000

B&K Precision

RUGGED CARRYING CASE FOR DAS240-

0

207030301

207030301

B&K Precision

SHUNT 0.01OHM 0.5% 30A MAX

0

910007200

910007200

B&K Precision

SHUNT 0.1 OHM (1% - 1A)

0

BE802

BE802

B&K Precision

EUROPEAN WALL ADPT W/OUT 12VDC

0

906002000

906002000

B&K Precision

RUGGED CARRYING CASE (DAS60)

0

RK02

RK02

B&K Precision

RACK MNT FOR BENCH DGTL

0

902407500

902407500

B&K Precision

DAS240-BAT MEASUREMENT MODULE CA

0

SP201

SP201

B&K Precision

CURR CLAMP 200A AC 10MV/A

0

837500526

837500526

B&K Precision

THERM PAPER SGL ROLL 10MX110MM

0

XLNTB

XLNTB

B&K Precision

SOLDERLESS OUTPUT CONNECTOR

0

SP261

SP261

B&K Precision

CURR CLAMP 1200A AC/DC 1MV/A

0

TL89F1

TL89F1

B&K Precision

4-TERMINAL FIXTURE FOR BENCH LCR

0

M404

M404

B&K Precision

ANTENNA DIPOLE 2.25 TO 2.65 GHZ

0

TL885D

TL885D

B&K Precision

SHORTING BAR FOR MODELS 885

0

TLPWR31

TLPWR31

B&K Precision

100 CM PREMIUM SPADE CONNECTOR T

0

902209000

902209000

B&K Precision

RACKMOUNT KIT FOR DAS220-BAT

0

TL885B

TL885B

B&K Precision

4-WIRE TEST LEAD

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top