Accessories

Image Part Number Description / PDF Quantity Rfq
72-146-5

72-146-5

NTE Electronics, Inc.

GRN INSULATOR FOR 72-144/145

324

WA-SOFTCASE

WA-SOFTCASE

Teledyne LeCroy

CASE SOFT CARRYING FOR WAVEACE

2

PK-ZS-003

PK-ZS-003

Teledyne LeCroy

STRAIGHT PIN LEAD SHORT 4/PC

1

CT2663

CT2663

Cal Test Electronics

INSULATED SPLICE, 4MM J - PAIR B

19

03K30R-MSOS3

03K30R-MSOS3

Rosenberger

PRECISION 3.5 CALIBRATION KIT

0

72-122-0

72-122-0

NTE Electronics, Inc.

BLACK INSULATOR FOR 72-120/121

436

CXT280

CXT280

Fluke Electronics

CASE PELICAN HARD 280 SERIES

0

M1002

M1002

Comet America

A1 INPUT MOD,MS LOGGER 4-20MA

20

VS-ACK-CPWR

VS-ACK-CPWR

Panduit Corporation

ACCESS CONTROL KIT FOR USE WITH

9

PK-ZS-004

PK-ZS-004

Teledyne LeCroy

LONG GROUND LEAD 4/PC

2

CT4140A-0.5A

CT4140A-0.5A

Cal Test Electronics

4MM INLINE FUSE ADAPTER, 1KV CAT

15

PK600ST-2

PK600ST-2

Teledyne LeCroy

RSSTR KT FOR D600ST-QC 56 OHM

0

BTL20

BTL20

Fluke Electronics

INTELLIGENT TEST PROBE SET W/EXT

0

ASTM 1 - 100G

ASTM 1 - 100G

Adam Equipment

ASTM WEIGHTS

50

P5S12S-00AS3

P5S12S-00AS3

Rosenberger

N TYPE SHORT

0

SVS-500

SVS-500

Fluke Electronics

SHAFT VOLTAGE SET AND MAG BASE

0

05K164-K20S3

05K164-K20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

ADPTR-B15

ADPTR-B15

Amprobe

LIGHT-CHECK ADAPTER B15

0

PK1-5MM-123

PK1-5MM-123

Teledyne LeCroy

HF COMP GND LEAD 22CM

2

M1013

M1013

Comet America

E0 INPUT 0-100MV, ISOLATED

20

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top