Accessories

Image Part Number Description / PDF Quantity Rfq
BP190

BP190

Fluke Electronics

RECHARGEABLE BATTERY PACK NIMH

7

51K170-C10S3

51K170-C10S3

Rosenberger

BNC CALIBRATION LOAD

0

183283-01

183283-01

NI

RS485 NULL-MODEM CABLE, DB-9 FEM

4

TL983P-KIT

TL983P-KIT

B&K Precision

3-PHASE KIT

3

PP001/002-2

PP001/002-2

Teledyne LeCroy

PP001/002 PROBE TIP-BNC

14

72-131-2

72-131-2

NTE Electronics, Inc.

RED INSULATOR FOR 72-129/130

293

A916

A916

TPI (Test Products International)

TPI TOTE BAG

3

72-122-2

72-122-2

NTE Electronics, Inc.

RED INSULATOR FOR 72-120/121

1285

P5K30R-MSOTS3

P5K30R-MSOTS3

Rosenberger

N TYPE CALIBRATION KIT

0

PK-ZS-025

PK-ZS-025

Teledyne LeCroy

QUAD FLAT PACK IC CLIP PR YL/GN

4

09K150-C10S3

09K150-C10S3

Rosenberger

PRECISION 2.40 CALIBRATION LOAD

0

72-146-4

72-146-4

NTE Electronics, Inc.

YEL INSULATOR FOR 72-144/145

159

72-119-5

72-119-5

NTE Electronics, Inc.

GRN INSULATOR FOR 72-116/117/118

1065

PGE01V100

PGE01V100

Bartovation

PHENYLTHIOUREA (PTC) TEST PAPER

100

72-165-9

72-165-9

NTE Electronics, Inc.

WHT INSULATOR FOR 72-163/164

753

T3DSO2000A-I2S

T3DSO2000A-I2S

Teledyne LeCroy

T3DSO2000A OSCILLOSCOPE SERIES I

0

FLUKE-700HTH-1

FLUKE-700HTH-1

Fluke Electronics

HYDRAULIC TEST HOSE 10000PSI

0

POK-FUS

POK-FUS

Pokit Innovations

POKITMETER FUSE SET

5

RM415

RM415

AIMtti

4U 13 RACK BLANKING PLATE FOR RM

0

FLK-TI-SBP3

FLK-TI-SBP3

Fluke Electronics

SMART BATTERY PACK 3

3

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top