Current Sensors

Image Part Number Description / PDF Quantity Rfq
MLX91220KDC-ABF-050-RE

MLX91220KDC-ABF-050-RE

Melexis

IC CURRENT SENSOR P&P 8SOIC

2950

MLX91205KDC-AAL-003-RE

MLX91205KDC-AAL-003-RE

Melexis

SENSOR CURRENT HALL 10MT AC/DC

0

ASA60-SG

ASA60-SG

Asentek

ANALOG 60A 10PPM 15V

1

ASI1000

ASI1000

Asentek

IND CURRENT TRANS 1000A .02%

1

GO 20 SME

GO 20 SME

LEM USA, Inc.

CURRENT TRANSDUCER INTEGRATED PR

556

ACS725LLCTR-30AB-T

ACS725LLCTR-30AB-T

Allegro MicroSystems

SENSOR CURRENT HALL 30A AC/DC

0

CQ206A

CQ206A

Asahi Kasei Microdevices / AKM Semiconductor

SENSOR CURRENT HALL 50A AC/DC

0

L18P010D15

L18P010D15

Tamura

SENSOR CURRENT HALL 10A AC/DC

409

CTL2002F

CTL2002F

Red Lion

SENSOR CURRENT 100A, 150A, 200A

0

HO 120-NP

HO 120-NP

LEM USA, Inc.

SENSOR CURRENT HALL 120A AC/DC

3446

ACS733KLATR-65AB-T

ACS733KLATR-65AB-T

Allegro MicroSystems

ACS733 - GALVANICALLY ISOLATED

0

T60404N4647X460

T60404N4647X460

VACUUMSCHMELZE GmbH & Co. KG.

CURRENT SENSOR, 50A, 3 PRI PINS,

120

L03S300D15

L03S300D15

Tamura

SENSOR CURRENT HALL 300A AC/DC

22

MLX91220KDC-ABF-025-RE

MLX91220KDC-ABF-025-RE

Melexis

IC CURRENT SENSOR P&P 8SOIC

0

ACHS-7121-500E

ACHS-7121-500E

Broadcom

HALL EFFECT IC, T/R+LF

0

HAC 800-S

HAC 800-S

LEM USA, Inc.

SENSOR CURRENT HALL 800A AC/DC

0

DC10-5V

DC10-5V

Aim Dynamics

VOLT TRANS AIM DYN 100VDC:5V

1

L34S1T2D15

L34S1T2D15

Tamura

SENSOR CURRENT HALL 1200A AC/DC

0

HO 180-P

HO 180-P

LEM USA, Inc.

SENSOR CURRENT HALL 180A AC/DC

20

LA03P021S05

LA03P021S05

Tamura

SENSOR

0

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.

RFQ BOM Call Skype Email
Top