Current Sensors

Image Part Number Description / PDF Quantity Rfq
HO 8-NP-0000

HO 8-NP-0000

LEM USA, Inc.

SENSOR CURRENT HALL 8A AC/DC

334

2904922

2904922

Phoenix Contact

PACT RCP-4000A-1A-D140

16

SCT-0750-025

SCT-0750-025

Aim Dynamics

CURRENT SENSE MAGNALAB 25A:333MV

72

CS0312U

CS0312U

CUI Devices

CURRENT SENSOR, OPEN LOOP, 3 A,

26

CSLA2DKI

CSLA2DKI

Honeywell Sensing and Productivity Solutions

SENSOR CURRENT HALL 400A AC/DC

0

2814647

2814647

Phoenix Contact

SENSOR CURRENT HALL 55A AC/DC

0

CSCA0050A000B15B01

CSCA0050A000B15B01

Honeywell Sensing and Productivity Solutions

SENSOR CURRENT HALL 50A AC/DC

24

HAIS 50-P

HAIS 50-P

LEM USA, Inc.

SENSOR CURRENT HALL 50A AC/DC

347

LA03P035S05

LA03P035S05

Tamura

SENSOR

0

MLX91221KDF-ABF-120-RE

MLX91221KDF-ABF-120-RE

Melexis

IC CURRENT SENSOR P&P 16SOIC

0

HAL 600-S

HAL 600-S

LEM USA, Inc.

SENSOR CURRENT HALL 600A AC/DC

21

20320800101

20320800101

HARTING

CURRENT SENSOR HAN OPEN LOOP 800

6

RCT-1800-1000

RCT-1800-1000

Aim Dynamics

CURRENT SENSE MAGNA 1000A:333MV

40

ACHS-7122-500E

ACHS-7122-500E

Broadcom

HALL EFFECT IC, T/R+LF

0

APR 50 B420L

APR 50 B420L

LEM USA, Inc.

SENSOR CURRENT 10A, 25A, 50A

0

MGS-1800-500

MGS-1800-500

Aim Dynamics

MGS-1800-0500 IS A THREE-PHASE R

5

HO 100-P

HO 100-P

LEM USA, Inc.

SENSOR CURRENT HALL 100A AC/DC

0

CSLA1CH

CSLA1CH

Honeywell Sensing and Productivity Solutions

SENSOR CURRENT HALL 150A AC/DC

36

CR5210-30

CR5210-30

CR Magnetics, Inc.

SENSOR CURRENT HALL 30A DC

0

SCT-0750-030

SCT-0750-030

Aim Dynamics

CURRENT SENSE MAGNALAB 30A:333MV

47

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.