Safety Relays

Image Part Number Description / PDF Quantity Rfq
8923.2C

8923.2C

Altech Corporation

SAFETY RELAY 12V DPDT BUSSED CON

0

56.OA03.0662N

56.OA03.0662N

Altech Corporation

OA5603 6V 6NO/2NC AGNI10+2UMAU I

0

56.OA03.1226S

56.OA03.1226S

Altech Corporation

OA560312V 2NO/6NC AGNI10+5UMAU I

0

256.OA11.2422C

256.OA11.2422C

Altech Corporation

2 CHANNEL MODULE 4P8A 24V 2NO/2N

0

56.OW70.1131C

56.OW70.1131C

Altech Corporation

OW5670110VDC2NO/2NC CONTACTS AGS

0

56.OW70.1122S

56.OW70.1122S

Altech Corporation

OW5670110VDC2NO/2NC CONTACTS AGN

0

56.OA11.0631C

56.OA11.0631C

Altech Corporation

OA5611 6V 3NO/1NC AGSN02+02UMAU

0

56.OA01.2422S

56.OA01.2422S

Altech Corporation

OA560124V 2NO/2NC AGNI10+5UMAU I

0

156.OA11.2431C

156.OA11.2431C

Altech Corporation

RELAY SAFETY 4PST 8A 24V

0

56.OA01.0622S

56.OA01.0622S

Altech Corporation

OA5601 6V 2NO/2NC AGNI10+5UMAU I

0

56.OA69.0600S

56.OA69.0600S

Altech Corporation

OA5669 6V 2CO AGNI10+ 5UMAU IP40

0

56.OA44.2431C

56.OA44.2431C

Altech Corporation

OA5644 24VDC3NO/1NC CONTACTS AGS

0

56.OA03.1235S

56.OA03.1235S

Altech Corporation

OA560312V 3NO/5NC AGNI10+5UMAU I

0

56.OA44.1131S

56.OA44.1131S

Altech Corporation

OA5644 110VDC3NO/1NC CONTACT AGN

0

56.OA01.1122C

56.OA01.1122C

Altech Corporation

OA5601110V2NO/2NC AGSN02+02UMAU

0

8924.2C

8924.2C

Altech Corporation

SAFETY RELAY 24V DPDT BUSSED CON

0

56.OW69.0611C

56.OW69.0611C

Altech Corporation

OW5669 6V 1NO/1NC AGSN02+02UMAU

0

56.OA70.1122S

56.OA70.1122S

Altech Corporation

OA5670110VDC2NO/2NC CONTACTS AGN

0

156.OA11.1222C

156.OA11.1222C

Altech Corporation

RELAY SAFETY 4PST 8A 12V

0

156.OA11.2422C

156.OA11.2422C

Altech Corporation

RELAY SAFETY 4PST 8A 24V

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email