Safety Relays

Image Part Number Description / PDF Quantity Rfq
56.OA42.1211S

56.OA42.1211S

Altech Corporation

OA5642 12VDC1NO/1NC CONTACTS AGN

0

56.OA01.1131S

56.OA01.1131S

Altech Corporation

OA5601110V3NO/1NC AGNI10+5UMAU I

0

56.OA44.1222S

56.OA44.1222S

Altech Corporation

OA5644 12VDC2NO/2NC CONTACTS AGN

0

56.OA01.1222S

56.OA01.1222S

Altech Corporation

OA560112V 2NO/2NC AGNI10+5UMAU I

0

56.OA44.6022N

56.OA44.6022N

Altech Corporation

OA5644 60VDC2NO/2NC CONTACTS AGN

0

56.OA42.0611C

56.OA42.0611C

Altech Corporation

OA5642 6VDC1NO/1NC CONTACTS AGSN

0

56.OW70.0631C

56.OW70.0631C

Altech Corporation

OW5670 6VDC2NO/2NC CONTACTS AGSN

0

56.OA01.1231S

56.OA01.1231S

Altech Corporation

OA560112V 3NO/1NC AGNI10+5UMAU I

0

56.OA70.1131C

56.OA70.1131C

Altech Corporation

OA5670110VDC3NO/1NC CONTACTS AGS

0

56.OA42.1111S

56.OA42.1111S

Altech Corporation

OA5642 110VDC1NO/1NC CONTACT AGN

0

456.OA02.2433C

456.OA02.2433C

Altech Corporation

SAFETY MODULE 4 CH 6P10A 12V 3NO

0

56.OA03.1253S

56.OA03.1253S

Altech Corporation

OA560312V 5NO/3NC AGNI10+5UMAU I

0

56.OA44.2422C

56.OA44.2422C

Altech Corporation

OA5644 24VDC2NO/2NC CONTACTS AGS

0

8946.2/P

8946.2/P

Altech Corporation

16CH RELAY MODULE 110V SPDT PANE

0

56.OA12.1233N

56.OA12.1233N

Altech Corporation

OA561212V 3NO/3NC AGNI10+2UMAU I

0

56.OA01.1222N

56.OA01.1222N

Altech Corporation

OA560112V 2NO/2NC AGNI10+2UMAU I

0

56.OW69.0600N

56.OW69.0600N

Altech Corporation

OW5669 6V 2CO AGNI10+2UMAU IP67

0

56.OA03.1244C

56.OA03.1244C

Altech Corporation

OA560312V 4NO/4NC AGSN02+02UMAU

0

56.OA02.1124S

56.OA02.1124S

Altech Corporation

OA5602110V2NO/4NC AGNI10+5UMAU I

0

8949.3N

8949.3N

Altech Corporation

SAFETY RELAY 12VDC DPDT CONTAC N

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities