Uninterruptible Power Supply (UPS) Systems

Image Part Number Description / PDF Quantity Rfq
A11J502SA002U

A11J502SA002U

Sanyo Denki SanUPS Products

A11J PARALLEL ONLINE UPS 5000VA

0

LDX-C120-12

LDX-C120-12

Power-One (Bel Power Solutions)

CONTROL UNITBATTERY CHARGER AND

0

SUINT1000LCD2U

SUINT1000LCD2U

Tripp Lite

SMARTONLINE 208/230V 1KVA 900W D

0

SV20KS1P0B

SV20KS1P0B

Tripp Lite

SMARTONLINE SV SERIES 20KVA SMAL

27

ASE202A001USP-WMPDU

ASE202A001USP-WMPDU

Sanyo Denki SanUPS Products

ONLINE UPS 2KVA 120V WITH BYPASS

0

E11A202B011UJP(J)

E11A202B011UJP(J)

Sanyo Denki SanUPS Products

2KVA 100/110/115/120V EPO

0

S5KD05ANRC1GNNC

S5KD05ANRC1GNNC

SolaHD

5 KVA ONLINE UPS W/ 1 BAT (D)

0

ASE102A001USP-WPDU

ASE102A001USP-WPDU

Sanyo Denki SanUPS Products

ONLINE UPS 1KVA 120V

0

BC450

BC450

Tripp Lite

STANDBY UPS 450VA 255W - 8 5-15R

354

SCV-20002

SCV-20002

Staco Energy Products Co.

SINGLE PHASE UPS, 2000VA, 230V

0

SU3000RTXLCD2UN

SU3000RTXLCD2UN

Tripp Lite

120V 3000VA 2700W DOUBLE-CONVERS

2

SV40KS2P0B

SV40KS2P0B

Tripp Lite

SMARTONLINE SV SERIES 40KVA SMAL

27

SMART1500TSU

SMART1500TSU

Tripp Lite

1440VA 1200W LINE-INTERACTIVE UP

27

OMNIVS800LCD

OMNIVS800LCD

Tripp Lite

800VA 475W LINE-INTERACTIVE UPS

20

SMART1000LCDU

SMART1000LCDU

Tripp Lite

UPS BACK UP SMART TOWER LCD ENER

15

SBN-20002

SBN-20002

Staco Energy Products Co.

STACO ENERGY'S UNISTAR SMART BUS

0

SMART1500RM2UL

SMART1500RM2UL

Tripp Lite

SMARTPRO UPS, LITHIUM BATTERY BA

0

S4K6U10KW0BATC

S4K6U10KW0BATC

SolaHD

UPS 10KVA 208/240 W/O BATT C

0

BC600TU

BC600TU

Tripp Lite

600VA 360W LINE-INTERACTIVE UPS

171

S5KF05ANNC1GNNC

S5KF05ANNC1GNNC

SolaHD

5 KVA ONLINE UPS W/ 1 BAT (F)

0

Uninterruptible Power Supply (UPS) Systems

1. Overview

An Uninterruptible Power Supply (UPS) is an electrical device that provides emergency power to connected equipment during utility power failures or voltage fluctuations. It ensures continuous operation, protects against data loss, and prevents hardware damage. UPS systems are critical in modern technology environments where power reliability is essential, such as data centers, healthcare facilities, and industrial automation systems.

2. Main Types and Functional Classification

Type Functional Features Application Examples
Offline/Standby UPS Switches to battery backup during outages; minimal protection Home computers, small office equipment
Line-Interactive UPS Regulates voltage without switching to battery; moderate protection Entry-level servers, networking equipment
Online Double-Conversion UPS Provides seamless power with zero transfer time; advanced isolation Data centers, medical imaging systems
Modular UPS Scalable design with hot-swappable components Cloud computing infrastructure, large enterprises
Smart UPS Integrated IoT connectivity for remote monitoring and management Smart buildings, industrial IoT systems

3. Structure and Components

A typical UPS system consists of:

  • Input Circuit Breaker: Controls power intake from utility
  • Rectifier: Converts AC to DC for battery charging
  • Battery Bank: Stores energy for backup power supply
  • Inverter: Converts DC back to AC for connected loads
  • Bypass Circuit: Routes power around internal components during maintenance
  • Control System: Monitors performance and manages power transitions

Advanced models include thermal management systems, harmonic filters, and network interface modules.

4. Key Technical Specifications

Parameter Importance
Power Capacity (kVA/kW) Determines maximum load support
Transfer Time (ms) Critical for sensitive equipment (0ms required for online UPS)
Runtime at Full Load (minutes) Defines emergency operation duration
Efficiency (%) Impacts energy costs and heat generation
Waveform Output Sinusoidal for critical equipment, simulated sine for basic loads
Battery Technology Lead-acid (cost-effective) vs. Lithium-ion (longer lifespan)

5. Application Fields

  • IT Infrastructure: Servers, storage arrays, network switches
  • Healthcare: MRI machines, patient monitoring systems
  • Manufacturing: PLC controllers, assembly line automation
  • Telecommunications: Base stations, fiber optic networks
  • Financial Sector: ATMs, trading platforms, data vaults

6. Leading Manufacturers and Products

Manufacturer Representative Product
Schneider Electric Galaxy VX (Modular UPS, 500kW scalable)
APC by Schneider Symmetra MW (3-phase modular system for data centers)
Eaton 93PM Series (99% efficient double-conversion UPS)
Vertiv NetSure DC Power System (Telco-specific UPS)
UPS5000-E (Lithium-ion battery integrated system)

7. Selection Recommendations

Key considerations:

  • Calculate total load requirements with 20% headroom
  • Assess required runtime (e.g., 10 minutes for graceful shutdown vs. hours for critical systems)
  • Environmental factors: operating temperature, humidity, and physical space
  • Management features: SNMP support, cloud monitoring, predictive maintenance
  • Total Cost of Ownership (TCO) including battery replacement cycles

Case Study: A 500kW data center selected modular online UPS systems with lithium-ion batteries, achieving 99.999% uptime and 15% energy savings through eco-mode operation.

8. Industry Trends

  • Modular Architecture: Growing adoption of scalable systems for flexible capacity planning
  • Green Energy Integration: Hybrid UPS systems combining solar and battery storage
  • AI-Driven Management: Predictive analytics for battery health and failure prevention
  • Edge Computing Support: Compact UPS solutions for distributed IT infrastructure
  • Standardization: Adoption of IEC 62040 and IEEE 1159 compliance as global benchmarks
RFQ BOM Call Skype Email
Top