Power Distribution, Surge Protectors

Image Part Number Description / PDF Quantity Rfq
P36G18M

P36G18M

Panduit Corporation

MSPO PDU, 24AMP, (30)C13, (6)C19

145

P06D18M

P06D18M

Panduit Corporation

MI PDU, 40AMP, (6)C19, HUBBELL C

227

P24E32M

P24E32M

Panduit Corporation

MS PDU, 48AMP, (12)C13, (12)C19,

131

P36F15M

P36F15M

Panduit Corporation

MO PDU, 24AMP, (30)C13, (6)C19,

13

P36E12M

P36E12M

Panduit Corporation

MS PDU, 28AMP, (30)C13, (6)C19,

1

P36B26M

P36B26M

Panduit Corporation

BASIC PDU, 30AMP, (30)C13(6)C19,

251

P08D09M

P08D09M

Panduit Corporation

MI PDU, 16AMP, (8)5-20R, NEMA 5-

2

P24B15M

P24B15M

Panduit Corporation

BASIC PDU, 30AMP, (20)C13(4)C19,

199

P16E19M

P16E19M

Panduit Corporation

MS PDU, 24AMP, (12)C13, (4)C19,

233

P22B05M

P22B05M

Panduit Corporation

BASIC PDU, 20AMP, (20)C13(2)C19,

4

P20B16M

P20B16M

Panduit Corporation

BASIC PDU, 30AMP, (20)C13, NEMA

4

GMSPO-A0302BL

GMSPO-A0302BL

Panduit Corporation

VERTICAL, (18) C13 LOCKING, (6)

2

P36B22M

P36B22M

Panduit Corporation

BASIC PDU, 30AMP, (30)C13(6)C19,

15

P24F05M

P24F05M

Panduit Corporation

MO PDU, 48AMP, (12)C13, (12)C19,

123

P12B30M

P12B30M

Panduit Corporation

BASIC PDU, 20AMP, (12)5-20R, NEM

1

P48B33M

P48B33M

Panduit Corporation

BASIC PDU, 60AMP, (36)C13(12)C19

0

P06D15M

P06D15M

Panduit Corporation

MI PDU, 40AMP, (6)C19, HUBBELL C

217

P16D20M

P16D20M

Panduit Corporation

MI PDU, 16AMP, (16) 5-20R, NEMA

31

P48G21M

P48G21M

Panduit Corporation

MSPO PDU, 48AMP, (36)C13,(12)C19

12

P24G04M

P24G04M

Panduit Corporation

MSPO PDU, 40AMP, (12)C13, (12)C1

112

Power Distribution, Surge Protectors

1. Overview

Power distribution and surge protection systems are critical components in modern electrical infrastructure. These systems ensure reliable power delivery, protect equipment from voltage spikes, and maintain operational continuity. Line protection devices safeguard against transient voltages, while power distribution units (PDUs) manage electricity allocation across networks. Surge protectors (SPDs) mitigate damage from lightning strikes or power surges. Together, these technologies form the backbone of stable power management in residential, commercial, and industrial applications.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Surge Protective Devices (SPDs)Divert transient surges to ground, maintain normal operationData centers, telecommunication systems
Isolation TransformersGalvanically isolate circuits, suppress electrical noiseHospitals, laboratory equipment
Uninterruptible Power Supplies (UPS)Provide backup power during outages, regulate voltageServer rooms, critical manufacturing systems
Power Distribution Units (PDUs)Monitor and distribute power to multiple outletsIT racks, data cabinets

3. Structure and Components

Typical surge protectors contain metal oxide varistors (MOVs), gas discharge tubes (GDTs), and thermal disconnects. PDUs feature hardened steel enclosures with multiple output sockets, integrated circuit breakers, and optional monitoring modules. UPS systems combine battery arrays, inverters, and automatic transfer switches. Advanced models incorporate IoT-enabled sensors for real-time voltage/current monitoring and predictive maintenance capabilities.

4. Key Technical Specifications

ParameterDescriptionImportance
Clamping VoltageMaximum voltage allowed during surgeDetermines protection level
Response TimeTime to activate protection (ns)Faster = better equipment safety
Energy Rating (Joules)Surge energy absorption capacityHigher = longer device lifespan
Network ManagementSNMP/Modbus connectivity supportEssential for system integration

5. Application Areas

  • IT Infrastructure: Server racks, network switches
  • Industrial: PLC systems, CNC machines
  • Healthcare: MRI/CT scanners, life-support systems
  • Renewables: Solar inverters, wind turbine controllers

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
APC by Schneider ElectricSmart-UPS On-LineDouble-conversion topology, 0ms transfer time
Eaton5P Series SPDHybrid technology, 400kA surge capacity
Phoenix ContactPT-IQ Power MonitorIoT-enabled energy analytics
RaritanPX Intelligent PDUPer-outlet metering, 15-year warranty

7. Selection Recommendations

Key considerations include:

  • Voltage compatibility with existing infrastructure
  • Surge current capacity (min. 20kA for critical systems)
  • Redundancy requirements for mission-critical loads
  • Environmental factors (temperature, humidity)
Case Study: Hospital CT scanner protection using Eaton's BDX-UPS system achieved 99.999% uptime through dual-battery redundancy and real-time diagnostics.

8. Industry Trends

Emerging developments include:

  • AI-powered predictive maintenance algorithms
  • Modular hybrid systems combining UPS + SPD functions
  • Integration with smart grid technologies
  • Increased adoption of wide bandgap semiconductors (SiC, GaN)
Market growth projections show 8.7% CAGR through 2030, driven by data center expansion and renewable energy integration requirements.

RFQ BOM Call Skype Email
Top