Power Distribution, Surge Protectors

Image Part Number Description / PDF Quantity Rfq
P24G02M

P24G02M

Panduit Corporation

MSPO PDU, 24AMP, (18)C13, (6)C19

143

P24D24M

P24D24M

Panduit Corporation

MI PDU, 16AMP, (20)C13, (4)C19,

2

P06B03M

P06B03M

Panduit Corporation

BASIC PDU, 60AMP, (6)C19, 460P9-

8

CMRPSV15SIL

CMRPSV15SIL

Panduit Corporation

VERTICAL POWER STRIP WITH A 15 A

3

P06D16M

P06D16M

Panduit Corporation

MI PDU, 24AMP, (6)C19, NEMA L15-

212

P48D32M

P48D32M

Panduit Corporation

MI PDU, 40AMP, (36)C13, (12)C19,

1285

CMRPSV20

CMRPSV20

Panduit Corporation

POWER STRIP VERTICAL, 20A, 10 NE

4

P24B14M

P24B14M

Panduit Corporation

BASIC PDU, 60AMP, (12)C13(12)C19

227

P36F17M

P36F17M

Panduit Corporation

MO PDU, 24AMP, (30)C13, (6)C19,

138

P24F01M

P24F01M

Panduit Corporation

MO PDU, 24AMP, (20)C13, (4)C19,

116

P24D31M

P24D31M

Panduit Corporation

MI PDU, 40AMP, (12)C13, (12)C19,

122

P12B46M

P12B46M

Panduit Corporation

BASIC PDU, 20AMP, (12)C13, NEMA

6

P36D26M

P36D26M

Panduit Corporation

MI PDU, 40AMP, (30)C13, (6)C19,

1

P12E21M

P12E21M

Panduit Corporation

MS PDU, 16AMP, (12)5-20R, NEMA 5

11

P36G19M

P36G19M

Panduit Corporation

MSPO PDU, 24AMP, (30)C13, (6)C19

1

P24D23M

P24D23M

Panduit Corporation

MI PDU, 24AMP, (24)5-20R, NEMA L

1

P24D01M

P24D01M

Panduit Corporation

MI PDU, 24AMP, (18)C13,(6)C19, N

19

P08E16M

P08E16M

Panduit Corporation

MS PDU, 16AMP, (8)5-20R, NEMA L5

2

P16D12M

P16D12M

Panduit Corporation

MI PDU, 24AMP, (16)5-20R, NEMA L

21

P24D34M

P24D34M

Panduit Corporation

MI PDU, 48AMP, (12)C13, (12)C19,

128

Power Distribution, Surge Protectors

1. Overview

Power distribution and surge protection systems are critical components in modern electrical infrastructure. These systems ensure reliable power delivery, protect equipment from voltage spikes, and maintain operational continuity. Line protection devices safeguard against transient voltages, while power distribution units (PDUs) manage electricity allocation across networks. Surge protectors (SPDs) mitigate damage from lightning strikes or power surges. Together, these technologies form the backbone of stable power management in residential, commercial, and industrial applications.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Surge Protective Devices (SPDs)Divert transient surges to ground, maintain normal operationData centers, telecommunication systems
Isolation TransformersGalvanically isolate circuits, suppress electrical noiseHospitals, laboratory equipment
Uninterruptible Power Supplies (UPS)Provide backup power during outages, regulate voltageServer rooms, critical manufacturing systems
Power Distribution Units (PDUs)Monitor and distribute power to multiple outletsIT racks, data cabinets

3. Structure and Components

Typical surge protectors contain metal oxide varistors (MOVs), gas discharge tubes (GDTs), and thermal disconnects. PDUs feature hardened steel enclosures with multiple output sockets, integrated circuit breakers, and optional monitoring modules. UPS systems combine battery arrays, inverters, and automatic transfer switches. Advanced models incorporate IoT-enabled sensors for real-time voltage/current monitoring and predictive maintenance capabilities.

4. Key Technical Specifications

ParameterDescriptionImportance
Clamping VoltageMaximum voltage allowed during surgeDetermines protection level
Response TimeTime to activate protection (ns)Faster = better equipment safety
Energy Rating (Joules)Surge energy absorption capacityHigher = longer device lifespan
Network ManagementSNMP/Modbus connectivity supportEssential for system integration

5. Application Areas

  • IT Infrastructure: Server racks, network switches
  • Industrial: PLC systems, CNC machines
  • Healthcare: MRI/CT scanners, life-support systems
  • Renewables: Solar inverters, wind turbine controllers

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
APC by Schneider ElectricSmart-UPS On-LineDouble-conversion topology, 0ms transfer time
Eaton5P Series SPDHybrid technology, 400kA surge capacity
Phoenix ContactPT-IQ Power MonitorIoT-enabled energy analytics
RaritanPX Intelligent PDUPer-outlet metering, 15-year warranty

7. Selection Recommendations

Key considerations include:

  • Voltage compatibility with existing infrastructure
  • Surge current capacity (min. 20kA for critical systems)
  • Redundancy requirements for mission-critical loads
  • Environmental factors (temperature, humidity)
Case Study: Hospital CT scanner protection using Eaton's BDX-UPS system achieved 99.999% uptime through dual-battery redundancy and real-time diagnostics.

8. Industry Trends

Emerging developments include:

  • AI-powered predictive maintenance algorithms
  • Modular hybrid systems combining UPS + SPD functions
  • Integration with smart grid technologies
  • Increased adoption of wide bandgap semiconductors (SiC, GaN)
Market growth projections show 8.7% CAGR through 2030, driven by data center expansion and renewable energy integration requirements.

RFQ BOM Call Skype Email
Top