Monitor - Relay Output

Image Part Number Description / PDF Quantity Rfq
2867979

2867979

Phoenix Contact

MON RELAY 3PHASE 2X2PDT 500VAC

2

601

601

Wickmann / Littelfuse

3-PHASE VOLTAGE MONITOR W/ DIS

0

84873222

84873222

Crouzet

M3US 208-480VAC UN-OVER VOLTAGE

0

ECS31AC

ECS31AC

Wickmann / Littelfuse

RELAY CUR SENSE

0

FB120A

FB120A

Wickmann / Littelfuse

RELAY TIME DELAY FLSH FAIL ALARM

3

DPB01CM48

DPB01CM48

Carlo Gavazzi

3PHASE OVER/UNDER VOLT MONITOR

22

K8DS-PM2

K8DS-PM2

Omron Automation & Safety Services

17.5 MM 3-PHASE SEQUENCE & PHA

3

DPA55CM44

DPA55CM44

Carlo Gavazzi

3PHASE VOLTAGE MONITOR RELAY

10

ECSH41AC

ECSH41AC

Wickmann / Littelfuse

RELAY CUR SENSE 120VAC 2-20A

22

PRS11031

PRS11031

Red Lion

1000-10,000 HZ 115V

0

DPA53CM48

DPA53CM48

Carlo Gavazzi

RELAY MONITOR 3PHASE 320-480

19

CR4395-EL-120-330-X-CD-ELR-I

CR4395-EL-120-330-X-CD-ELR-I

CR Magnetics, Inc.

RELAY AC CUR SENS 120VAC CHAS MT

0

84874320

84874320

Crouzet

RELAY MONITOR SPED 24-240VAC ADJ

0

2885249

2885249

Phoenix Contact

MON RELAY 3PHASE 2X2PDT 690VAC

0

2866051

2866051

Phoenix Contact

ELECTRONIC MONITORING RELAY

1

DIB01CM24100A

DIB01CM24100A

Carlo Gavazzi

MONITOR OVER/UNDER CURR 100A

10

HLMUDLAAA

HLMUDLAAA

Wickmann / Littelfuse

3 PHASE VOLTAGE MONITOR

1

202-OEM

202-OEM

Wickmann / Littelfuse

3 PH VOLT MONITOR 48 PCS

0

PRS10101

PRS10101

Red Lion

1-10 HZ 115V

0

CMB-120-AFA1

CMB-120-AFA1

ATC

CURRENT MONITOR RELAY

10

Monitor - Relay Output

1. Overview

A Monitor - Relay Output device is an industrial automation component that combines signal monitoring capabilities with relay-based output control. It detects electrical or process signals (e.g., voltage, current, temperature) and triggers relay actions to manage machinery, safety systems, or process equipment. These devices are critical in modern industrial systems for ensuring precise control, fault detection, and automated decision-making in complex workflows.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Relay Output MonitorUses physical contacts for high-current switchingMotor starters, HVAC systems
Solid-State Relay Output MonitorZero-contact switching with semiconductor devicesPrecision heating systems, CNC machines
Programmable Logic Relay MonitorConfigurable logic and timing functionsAssembly line controls, packaging machines
Multi-Function Relay MonitorCombines monitoring, logging, and communicationEnergy management systems, water treatment

3. Structure and Components

Typical construction includes: - Housing: Industrial-grade plastic/metal enclosure (IP65-IP67 rating) - Relay Module: Electromechanical or solid-state switching elements - Input Interface: Signal conditioning circuits for sensor compatibility - Control Board: Microprocessor with embedded firmware - Communication Ports: RS-485, Modbus TCP, or Ethernet/IP - Power Supply: 24V DC or 110/220V AC universal input - Status Indicators: LED arrays for operational feedback

4. Key Technical Specifications

ParameterImportance
Rated Voltage (AC/DC): 5-250VDetermines compatibility with control systems
Contact Current: 1-16ADefines maximum load capacity
Response Time: 1-50msCritical for high-speed automation
Electrical Life: 10 -10 cyclesAffects maintenance intervals
Insulation Resistance: >100M Ensures safety and noise immunity
Operating Temperature: -20 C to +70 CDefines environmental tolerance
Communication Protocol SupportEnables system integration

5. Application Fields

  • Manufacturing: PLC-controlled production lines, robotic arms
  • Energy: Substation monitoring, renewable energy systems
  • Transportation: Rail signaling systems, traffic light controllers
  • Building Automation: Elevator controls, HVAC sequencers
  • Process Industry: Pump controls in oil/gas facilities

6. Leading Manufacturers and Products

ManufacturerRepresentative Product
Siemens3RT2 relay series with IO-Link integration
OmronMY2 series industrial relays with LED indicators
Schneider ElectricTeSys Giga relays for motor control
ABBCR-P series programmable relay monitors
Phoenix ContactPSR-SCP-24UC relay modules

7. Selection Recommendations

Key considerations: - Load type (resistive/inductive) and power requirements - Environmental factors (temperature, humidity, vibration) - Required certification (CE, UL, ATEX) - Communication protocol compatibility - Redundancy requirements for safety-critical systems

Case Study: In a food processing plant, IP67-rated solid-state relays with food-grade housing were selected for washdown areas to ensure reliability under frequent cleaning cycles.

8. Industry Trends

Current developments include: - Integration with IIoT platforms for predictive maintenance - Edge computing capabilities for real-time decision-making - Increased adoption of wireless relay monitoring systems - Development of intrinsically safe designs for hazardous environments - Energy-efficient relay architectures with reduced coil power consumption

RFQ BOM Call Skype Email