Monitor - Relay Output

Image Part Number Description / PDF Quantity Rfq
K8DT-PH1CN

K8DT-PH1CN

Omron Automation & Safety Services

3PHSE 3WIRE PHSELSS RLY PSH IN

3

84871031

84871031

Crouzet

CONTROL RLY CURRENT 24VAC .1-10A

0

102A2

102A2

Wickmann / Littelfuse

3-PHASE VOLTAGE MONITOR/ 190-4

460

84873022

84873022

Crouzet

RELAY MONITOR 3PHASE 208-480V

8

PRS10012

PRS10012

Red Lion

0.1-1 HZ 230V

0

K8DT-TH1CD

K8DT-TH1CD

Omron Automation & Safety Services

TEMP MONTRG RELY TC/RTD PSH IN

1

K8DT-AS1TA

K8DT-AS1TA

Omron Automation & Safety Services

CURNTTRANSNPN 2-500MA PSH IN

5

50R200

50R200

Wickmann / Littelfuse

1-PHASE VOLTAGE MONITOR/ 190-2

9

7940012190

7940012190

Weidmuller

UTCAR

1

K8AK-PH1 200/500VAC

K8AK-PH1 200/500VAC

Omron Automation & Safety Services

3-PHASE 3WIRE PHASE LOSS

55

TVW8510S0.4S

TVW8510S0.4S

Wickmann / Littelfuse

3 PHASE VOLTAGE MONITOR

0

PRS11032

PRS11032

Red Lion

1000-10,000 HZ 230V

0

K8AK-VW3 24VAC/DC

K8AK-VW3 24VAC/DC

Omron Automation & Safety Services

UNDROVR VOLT RELAY 20 TO 600 V

1

TCSH5B

TCSH5B

Wickmann / Littelfuse

CURRENT SENSOR

0

LSRU-115-OU-3

LSRU-115-OU-3

Wickmann / Littelfuse

LOAD SENSOR/ 115V/ 25-100A/ OC

0

PRS11022

PRS11022

Red Lion

100-1000 HZ 230V

0

PLR480A

PLR480A

Wickmann / Littelfuse

RELAY 380-500VAC VOLT MONITOR

2

MAR-120-ACAC

MAR-120-ACAC

ATC

MOTOR AUTO-RESTART RELAY

10

V4PF480Y/277VSYTK02

V4PF480Y/277VSYTK02

Aim Dynamics

V4PF480Y/277VSYTK02 IS A 3-PHASE

1

231-INSIDER-P

231-INSIDER-P

Wickmann / Littelfuse

1-PHASE PUMPSAVERPLUS/230V/ FO

3

Monitor - Relay Output

1. Overview

A Monitor - Relay Output device is an industrial automation component that combines signal monitoring capabilities with relay-based output control. It detects electrical or process signals (e.g., voltage, current, temperature) and triggers relay actions to manage machinery, safety systems, or process equipment. These devices are critical in modern industrial systems for ensuring precise control, fault detection, and automated decision-making in complex workflows.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Relay Output MonitorUses physical contacts for high-current switchingMotor starters, HVAC systems
Solid-State Relay Output MonitorZero-contact switching with semiconductor devicesPrecision heating systems, CNC machines
Programmable Logic Relay MonitorConfigurable logic and timing functionsAssembly line controls, packaging machines
Multi-Function Relay MonitorCombines monitoring, logging, and communicationEnergy management systems, water treatment

3. Structure and Components

Typical construction includes: - Housing: Industrial-grade plastic/metal enclosure (IP65-IP67 rating) - Relay Module: Electromechanical or solid-state switching elements - Input Interface: Signal conditioning circuits for sensor compatibility - Control Board: Microprocessor with embedded firmware - Communication Ports: RS-485, Modbus TCP, or Ethernet/IP - Power Supply: 24V DC or 110/220V AC universal input - Status Indicators: LED arrays for operational feedback

4. Key Technical Specifications

ParameterImportance
Rated Voltage (AC/DC): 5-250VDetermines compatibility with control systems
Contact Current: 1-16ADefines maximum load capacity
Response Time: 1-50msCritical for high-speed automation
Electrical Life: 10 -10 cyclesAffects maintenance intervals
Insulation Resistance: >100M Ensures safety and noise immunity
Operating Temperature: -20 C to +70 CDefines environmental tolerance
Communication Protocol SupportEnables system integration

5. Application Fields

  • Manufacturing: PLC-controlled production lines, robotic arms
  • Energy: Substation monitoring, renewable energy systems
  • Transportation: Rail signaling systems, traffic light controllers
  • Building Automation: Elevator controls, HVAC sequencers
  • Process Industry: Pump controls in oil/gas facilities

6. Leading Manufacturers and Products

ManufacturerRepresentative Product
Siemens3RT2 relay series with IO-Link integration
OmronMY2 series industrial relays with LED indicators
Schneider ElectricTeSys Giga relays for motor control
ABBCR-P series programmable relay monitors
Phoenix ContactPSR-SCP-24UC relay modules

7. Selection Recommendations

Key considerations: - Load type (resistive/inductive) and power requirements - Environmental factors (temperature, humidity, vibration) - Required certification (CE, UL, ATEX) - Communication protocol compatibility - Redundancy requirements for safety-critical systems

Case Study: In a food processing plant, IP67-rated solid-state relays with food-grade housing were selected for washdown areas to ensure reliability under frequent cleaning cycles.

8. Industry Trends

Current developments include: - Integration with IIoT platforms for predictive maintenance - Edge computing capabilities for real-time decision-making - Increased adoption of wireless relay monitoring systems - Development of intrinsically safe designs for hazardous environments - Energy-efficient relay architectures with reduced coil power consumption

RFQ BOM Call Skype Email
Top