Arrays, Signal Transformers

Image Part Number Description / PDF Quantity Rfq
PF0553.473NLT

PF0553.473NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 47UH SMD

0

PF0552.224NLT

PF0552.224NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 220UH SMD

0

PF0553.152NLT

PF0553.152NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 1.4UH SMD

0

PF0553.682NLT

PF0553.682NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 7.4UH SMD

0

PF0553.105NLT

PF0553.105NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 1MH SMD

0

PF0552.104NLT

PF0552.104NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 100UH SMD

0

PF0552.153NLT

PF0552.153NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 15UH SMD

0

PF0553.471NLT

PF0553.471NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 430NH SMD

0

P0399NL

P0399NL

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 10.1UH SMD

0

P0399NLT

P0399NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 10.1UH SMD

0

PF0552.682NLT

PF0552.682NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 6.6UH SMD

0

PF0553.822NLT

PF0553.822NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 8.9UH SMD

0

BX8153NL

BX8153NL

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 5UH SMD

0

PA0135.331NLT

PA0135.331NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 82.5NH SMD

0

PA0135.471NLT

PA0135.471NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 118NH SMD

0

P0106NLT

P0106NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 17.3UH SMD

0

BX8153NLT

BX8153NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 5UH SMD

0

PA0135.102NLT

PA0135.102NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 250NH SMD

0

P0402

P0402

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 40.5UH SMD

0

P0106NL

P0106NL

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 17.3UH SMD

0

Arrays, Signal Transformers

1. Overview

Inductors, coils, chokes, arrays, and signal transformers are fundamental passive components in electronic systems. Inductors store energy in magnetic fields, chokes suppress high-frequency noise, arrays integrate multiple magnetic elements, and signal transformers enable voltage conversion and galvanic isolation. These components are critical in power management, signal processing, electromagnetic interference (EMI) mitigation, and communication systems. Their advancements drive miniaturization, efficiency, and performance in modern electronics.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Wire-wound InductorsHigh inductance values, low DC resistanceSwitching power supplies
Ferrite Bead ChokesHigh impedance at high frequenciesEMI filtering in USB interfaces
Common-mode Choke ArraysSuppress differential and common-mode noiseIndustrial motor drives
Signal TransformersGalvanic isolation, voltage scalingTelecom network interfaces
Thin-film Inductor ArraysUltra-low profile, tight couplingRF front-end modules

3. Structure and Composition

Typical structures include:

  • Inductors: Wound conductive wire (copper/enamelled aluminum) on magnetic cores (ferrite, powdered iron)
  • Chokes: Toroidal or drum cores with single/dual windings
  • Arrays: Monolithic integration of multiple chokes/inductors in single package
  • Signal Transformers: Primary/secondary coils with electrostatic shielding, E-I or toroidal cores

4. Key Technical Specifications

ParameterDescriptionImportance
Inductance (L)Defines energy storage capacity ( H-mH range)Determines filtering performance
Rated CurrentMax DC/AC current before saturationPrevents core saturation in power circuits
DCRDC resistance of windingsAffects power efficiency
Self-resonant FrequencyFrequency where parasitic capacitance dominatesLimits usable frequency range
Turns RatioPrimary/secondary winding ratioDefines voltage transformation ratio

5. Application Fields

Key industries:

  • Telecommunications: Base station power systems, optical transceivers
  • Consumer Electronics: Mobile chargers, LED drivers
  • Automotive: EV battery management systems, ADAS sensors
  • Industrial: Programmable logic controllers (PLCs), inverters

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductsKey Features
TDKINDUCTOR,Wire-wound: VLS6045EX6.0 4.5 4.5mm, 120A rated current
CoilcraftCommon-mode Choke: 1140081.8kV isolation, 100MHz bandwidth
BournsSignal Transformer: SM41121:1:1:1 ratio, 1500V isolation
Pulse ElectronicsLAN Transformer: HX4008NLIntegrated magnetics for Gigabit Ethernet
SumidaPower Choke: CDRH3D283.3 H-100 H, 125A peak current

7. Selection Guidelines

Consider:

  • Inductance value and tolerance ( 20% typical for power chokes)
  • Operating frequency vs. self-resonant frequency
  • Thermal management (temperature rise 40 C)
  • Package size (0402-2200 for surface-mount devices)
  • Isolation voltage ( 1.5kV for industrial applications)

8. Industry Trends

Emerging trends:

  • Miniaturization: 01005-sized inductors for wearable devices
  • High-frequency operation: Multi-GHz transformers for 5G infrastructure
  • Integrated magnetics: Combined inductors/transformers in SiP solutions
  • Advanced materials: Amorphous/nanocrystalline cores for high-efficiency EV chargers
  • Automotive-grade reliability: AEC-Q200 qualified components for e-mobility

RFQ BOM Call Skype Email
Top