Arrays, Signal Transformers

Image Part Number Description / PDF Quantity Rfq
PF0553.332NLT

PF0553.332NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 2.8UH SMD

0

PF0553.474NLT

PF0553.474NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 470UH SMD

0

PF0553.684NLT

PF0553.684NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 680UH SMD

0

P0183NLT

P0183NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 91UH SMD

0

PF0553.104NLT

PF0553.104NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 100UH SMD

0

PF0553.102NLT

PF0553.102NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 860NH SMD

0

PF0553.823NLT

PF0553.823NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 80UH SMD

0

PF0552.222NLT

PF0552.222NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 2.2UH SMD

0

PF0552.102NLT

PF0552.102NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 910NH SMD

0

PF0552.152NLT

PF0552.152NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 1.5UH SMD

0

PA3144HL

PA3144HL

PulseLarsen Antenna

INDUCT ARRAY 4 COIL SMD

0

P0178NLT

P0178NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 15.7UH SMD

0

PF0553.154NLT

PF0553.154NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 150UH SMD

0

PF0552.332NLT

PF0552.332NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 3.1UH SMD

0

P0179NLT

P0179NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 22.1UH SMD

0

PF0553.334NLT

PF0553.334NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 330UH SMD

0

PF0553.824NLT

PF0553.824NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 830UH SMD

0

P0182NL

P0182NL

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 67.5UH SMD

0

PF0552.824NLT

PF0552.824NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 830UH SMD

0

PF0552.822NLT

PF0552.822NLT

PulseLarsen Antenna

INDUCT ARRAY 2 COIL 8.1UH SMD

0

Arrays, Signal Transformers

1. Overview

Inductors, coils, chokes, arrays, and signal transformers are fundamental passive components in electronic systems. Inductors store energy in magnetic fields, chokes suppress high-frequency noise, arrays integrate multiple magnetic elements, and signal transformers enable voltage conversion and galvanic isolation. These components are critical in power management, signal processing, electromagnetic interference (EMI) mitigation, and communication systems. Their advancements drive miniaturization, efficiency, and performance in modern electronics.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Wire-wound InductorsHigh inductance values, low DC resistanceSwitching power supplies
Ferrite Bead ChokesHigh impedance at high frequenciesEMI filtering in USB interfaces
Common-mode Choke ArraysSuppress differential and common-mode noiseIndustrial motor drives
Signal TransformersGalvanic isolation, voltage scalingTelecom network interfaces
Thin-film Inductor ArraysUltra-low profile, tight couplingRF front-end modules

3. Structure and Composition

Typical structures include:

  • Inductors: Wound conductive wire (copper/enamelled aluminum) on magnetic cores (ferrite, powdered iron)
  • Chokes: Toroidal or drum cores with single/dual windings
  • Arrays: Monolithic integration of multiple chokes/inductors in single package
  • Signal Transformers: Primary/secondary coils with electrostatic shielding, E-I or toroidal cores

4. Key Technical Specifications

ParameterDescriptionImportance
Inductance (L)Defines energy storage capacity ( H-mH range)Determines filtering performance
Rated CurrentMax DC/AC current before saturationPrevents core saturation in power circuits
DCRDC resistance of windingsAffects power efficiency
Self-resonant FrequencyFrequency where parasitic capacitance dominatesLimits usable frequency range
Turns RatioPrimary/secondary winding ratioDefines voltage transformation ratio

5. Application Fields

Key industries:

  • Telecommunications: Base station power systems, optical transceivers
  • Consumer Electronics: Mobile chargers, LED drivers
  • Automotive: EV battery management systems, ADAS sensors
  • Industrial: Programmable logic controllers (PLCs), inverters

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductsKey Features
TDKINDUCTOR,Wire-wound: VLS6045EX6.0 4.5 4.5mm, 120A rated current
CoilcraftCommon-mode Choke: 1140081.8kV isolation, 100MHz bandwidth
BournsSignal Transformer: SM41121:1:1:1 ratio, 1500V isolation
Pulse ElectronicsLAN Transformer: HX4008NLIntegrated magnetics for Gigabit Ethernet
SumidaPower Choke: CDRH3D283.3 H-100 H, 125A peak current

7. Selection Guidelines

Consider:

  • Inductance value and tolerance ( 20% typical for power chokes)
  • Operating frequency vs. self-resonant frequency
  • Thermal management (temperature rise 40 C)
  • Package size (0402-2200 for surface-mount devices)
  • Isolation voltage ( 1.5kV for industrial applications)

8. Industry Trends

Emerging trends:

  • Miniaturization: 01005-sized inductors for wearable devices
  • High-frequency operation: Multi-GHz transformers for 5G infrastructure
  • Integrated magnetics: Combined inductors/transformers in SiP solutions
  • Advanced materials: Amorphous/nanocrystalline cores for high-efficiency EV chargers
  • Automotive-grade reliability: AEC-Q200 qualified components for e-mobility

RFQ BOM Call Skype Email
Top