Power Line Filter Modules

Image Part Number Description / PDF Quantity Rfq
FMAC-0934-5010

FMAC-0934-5010

Schurter

LINE FILTER 480/520VAC 50A CHASS

8

5500.2642.04

5500.2642.04

Schurter

LINE FILTER 125/250VAC 6A CHAS

4

FMBB-3409-0340

FMBB-3409-0340

Schurter

FMBB EP FILTER 1PH 2ST 3A 250VAC

30

5500.2651.01

5500.2651.01

Schurter

LINE FILTER 125/250VAC 3A CHAS

30

5500.2633.04

5500.2633.04

Schurter

LINE FILTER 125/250VAC 6A CHAS

15

5500.2010

5500.2010

Schurter

LINE FILTER 125/250VAC 3A TH

16

FMAB-N6PG-0146

FMAB-N6PG-0146

Schurter

HV FILTER 1PH 1ST N 1A 277VAC M5

0

FMER-G92W-S557

FMER-G92W-S557

Schurter

LINE FILTER 1.2KVDC 1.5KA CHASS

0

5500.2232

5500.2232

Schurter

LINE FILTER 80VDC 20A CHASS MNT

5

5500.2641.04

5500.2641.04

Schurter

LINE FILTER 125/250VAC 3A CHAS

15

5500.2656.07

5500.2656.07

Schurter

LINE FILTER 125/250VAC 20A CHASS

20

5500.2655.04

5500.2655.04

Schurter

LINE FILTER 125/250VAC 16A CHASS

15

FPBB-W3TI-0690.VD

FPBB-W3TI-0690.VD

Schurter

LINE FILTER 240VAC 6A

19

5500.2016

5500.2016

Schurter

LINE FILTER 125/250VAC 1.6A TH

46970

5500.2631.01

5500.2631.01

Schurter

LINE FILTER 125/250VAC 3A CHAS

4030

FMAD-33SZ-0342.HP

FMAD-33SZ-0342.HP

Schurter

FMAD CP FILT 3PH+N 1ST 3A 520VAC

8

5500.2122

5500.2122

Schurter

LINE FILTER 125/250VAC 1A TH

0

FMER-G92P-2517

FMER-G92P-2517

Schurter

LINE FILTER 1.2KVDC 25A CHASS

10

5500.2656.01

5500.2656.01

Schurter

LINE FILTER 125/250VAC 20A CHASS

30

5500.2637.01

5500.2637.01

Schurter

LINE FILTER 125/250VAC 16A CHASS

24

Power Line Filter Modules

1. Overview

Power Line Filter Modules (PLFMs) are electromagnetic interference (EMI) suppression devices designed to mitigate conducted noise in electrical systems. They ensure compliance with electromagnetic compatibility (EMC) standards by attenuating high-frequency noise while allowing desired power frequencies to pass. Their importance grows with increasing electrification and connectivity in modern applications like renewable energy systems, industrial automation, and medical electronics.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
Differential Mode FilterSuppresses asymmetric noise between live/neutral conductorsMotor drives, variable frequency drives
Common Mode FilterAttenuates symmetric noise between conductors and groundMedical imaging equipment, data centers
Combined FilterIntegrates differential and common mode suppressionIndustrial control cabinets, test equipment
High-Frequency FilterTargets noise above 1MHz with specialized componentsWireless base stations, satellite communication

3. Structure and Components

Typical PLFM construction includes: - Die-cast aluminum housing for EMI shielding - X/Y capacitors (ceramic or film type) for differential/common mode filtering - Toroidal or multi-hole inductors for noise suppression - Integrated thermal fuses and discharge resistors - IEC standard connectors (e.g., C13/C14) or terminal blocks - Epoxy sealing for environmental protection

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeTypically 150kHz-100MHzDetermines noise bandwidth attenuation
Voltage Rating100-600VAC/DCDefines operational safety margin
Insertion Loss10-100dB at target frequenciesQuantifies noise reduction capability
Current Capacity0.5-100AAffects power delivery capability
Temperature Range-40 C to +125 CEnsures environmental reliability

5. Application Areas

Key industries and equipment: - Industrial Automation: PLC control cabinets, CNC machines - Medical: MRI scanners, patient monitoring systems - Communication: 5G base stations, network servers - Renewable Energy: Solar inverters, wind turbine controllers - Aerospace: Avionics power systems, satellite payloads - Consumer Electronics: EV charging stations, smart home systems

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
SchaffnerFN 208080A rating, 3-phase filter for industrial drives
TDK-LambdaDFM1K1kW power line filter with medical safety certification
MTE CorporationPro-NetModular filter for industrial Ethernet applications
API TechnologiesPLF-300Military-grade filter for aerospace systems

7. Selection Guidelines

Key considerations: - Match voltage/current ratings with system requirements - Verify insertion loss curves at specific noise frequencies - Consider physical dimensions and cooling requirements - Ensure compliance with relevant standards (e.g., IEC 60939) - Evaluate environmental conditions (temperature, humidity, vibration) - Assess certification needs (CE, UL, MIL-STD)

8. Industry Trends

Market developments include: - Increasing demand for high-frequency filters (>10MHz) due to 5G/6G adoption - Miniaturization for EV and portable medical device applications - Integration with smart monitoring capabilities (IoT-enabled filters) - Growth in wide bandgap semiconductor compatible filters (SiC/GaN) - Stricter EMC regulations driving customized filter solutions - Market CAGR projected at 6.8% (2023-2030) according to industry reports