Power Line Filter Modules

Image Part Number Description / PDF Quantity Rfq
FMBB-34MD-1640

FMBB-34MD-1640

Schurter

FMBB EP FILTER 1PH 2ST 16A 250VA

9

FMBC-0996-8000

FMBC-0996-8000

Schurter

LINE FILTER 480VAC 80A CHASS MNT

0

5500.2050

5500.2050

Schurter

LINE FILTER 125/250VAC 30A CHASS

4

5500.2658.09

5500.2658.09

Schurter

LINE FILTER 125/250VAC 60A CHASS

0

FPBB-W3RI-1090

FPBB-W3RI-1090

Schurter

LINE FILTER 48VDC 10A DIN RAIL

24

5500.2126

5500.2126

Schurter

LINE FILTER 125/250VAC 3A TH

20

5500.2039

5500.2039

Schurter

LINE FILTER 125/250VAC 1A CHAS

14100

5500.2650.04

5500.2650.04

Schurter

LINE FILTER 125/250VAC 1A CHAS

15

5500.0655.1

5500.0655.1

Schurter

LINE FILTER 125/250VAC 6A TH

200

5500.2081

5500.2081

Schurter

LINE FILTER 125/250VAC 10A CHASS

0

FPBB-W3RI-0690.VD

FPBB-W3RI-0690.VD

Schurter

LINE FILTER 48VDC 6A DIN RAIL

12

FPBB-V3RI-0190

FPBB-V3RI-0190

Schurter

LINE FILTER 250VAC 1A

16

5500.2029

5500.2029

Schurter

LINE FILTER 125/250VAC 6A CHAS

0

5500.2225

5500.2225

Schurter

LINE FILTER 43/80VDC 15A CHAS

75

5500.2034

5500.2034

Schurter

LINE FILTER 125/250VAC 20A CHASS

8

5500.2119

5500.2119

Schurter

LINE FILTER 125/250VAC 4A TH

0

5500.2634.04

5500.2634.04

Schurter

LINE FILTER 125/250VAC 8A CHAS

17

5500.2632.07

5500.2632.07

Schurter

LINE FILTER 125/250VAC 4A CHAS

15

FPBB-U3RI-1690.VD

FPBB-U3RI-1690.VD

Schurter

LINE FILTER 250VAC 16A

0

5500.2615.01

5500.2615.01

Schurter

FMBB NEO FILTER 1PH 2ST D 16A 25

2

Power Line Filter Modules

1. Overview

Power Line Filter Modules (PLFMs) are electromagnetic interference (EMI) suppression devices designed to mitigate conducted noise in electrical systems. They ensure compliance with electromagnetic compatibility (EMC) standards by attenuating high-frequency noise while allowing desired power frequencies to pass. Their importance grows with increasing electrification and connectivity in modern applications like renewable energy systems, industrial automation, and medical electronics.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
Differential Mode FilterSuppresses asymmetric noise between live/neutral conductorsMotor drives, variable frequency drives
Common Mode FilterAttenuates symmetric noise between conductors and groundMedical imaging equipment, data centers
Combined FilterIntegrates differential and common mode suppressionIndustrial control cabinets, test equipment
High-Frequency FilterTargets noise above 1MHz with specialized componentsWireless base stations, satellite communication

3. Structure and Components

Typical PLFM construction includes: - Die-cast aluminum housing for EMI shielding - X/Y capacitors (ceramic or film type) for differential/common mode filtering - Toroidal or multi-hole inductors for noise suppression - Integrated thermal fuses and discharge resistors - IEC standard connectors (e.g., C13/C14) or terminal blocks - Epoxy sealing for environmental protection

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeTypically 150kHz-100MHzDetermines noise bandwidth attenuation
Voltage Rating100-600VAC/DCDefines operational safety margin
Insertion Loss10-100dB at target frequenciesQuantifies noise reduction capability
Current Capacity0.5-100AAffects power delivery capability
Temperature Range-40 C to +125 CEnsures environmental reliability

5. Application Areas

Key industries and equipment: - Industrial Automation: PLC control cabinets, CNC machines - Medical: MRI scanners, patient monitoring systems - Communication: 5G base stations, network servers - Renewable Energy: Solar inverters, wind turbine controllers - Aerospace: Avionics power systems, satellite payloads - Consumer Electronics: EV charging stations, smart home systems

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
SchaffnerFN 208080A rating, 3-phase filter for industrial drives
TDK-LambdaDFM1K1kW power line filter with medical safety certification
MTE CorporationPro-NetModular filter for industrial Ethernet applications
API TechnologiesPLF-300Military-grade filter for aerospace systems

7. Selection Guidelines

Key considerations: - Match voltage/current ratings with system requirements - Verify insertion loss curves at specific noise frequencies - Consider physical dimensions and cooling requirements - Ensure compliance with relevant standards (e.g., IEC 60939) - Evaluate environmental conditions (temperature, humidity, vibration) - Assess certification needs (CE, UL, MIL-STD)

8. Industry Trends

Market developments include: - Increasing demand for high-frequency filters (>10MHz) due to 5G/6G adoption - Miniaturization for EV and portable medical device applications - Integration with smart monitoring capabilities (IoT-enabled filters) - Growth in wide bandgap semiconductor compatible filters (SiC/GaN) - Stricter EMC regulations driving customized filter solutions - Market CAGR projected at 6.8% (2023-2030) according to industry reports