Thermal - Liquid Cooling, Heating

Image Part Number Description / PDF Quantity Rfq
9421502.T

9421502.T

JULABO

PRESTO W50T, REFRIG/HEAT CIRC

1

9352752N

9352752N

JULABO

FP52-SL REFIG/HEAT CIRC

3

ATS-HE22-C7-R0

ATS-HE22-C7-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH ONE 48V DC F

2

ATS-TCP-1003

ATS-TCP-1003

Advanced Thermal Solutions, Inc.

TUBED COLD PLATE

7

ATS-HE25-C1-R0

ATS-HE25-C1-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER 21.58X12X2.1"

3

ATS-HE23-C6-R0

ATS-HE23-C6-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH ONE 48V DC F

2

ATS-HE24-C7-R0

ATS-HE24-C7-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH ONE 48V DC F

2

CP4A-114A-108E

CP4A-114A-108E

Ohmite

COLD PLATE HEAT SINK 0.43C/W

25

9666025

9666025

JULABO

FL2506 CHILLER, 2.5KW, 230V

1

ATS-CP-1004

ATS-CP-1004

Advanced Thermal Solutions, Inc.

MINI CHANNEL COLD PLATE

7

ATS-TCP-1002

ATS-TCP-1002

Advanced Thermal Solutions, Inc.

TUBED COLD PLATE

10

ATS-HE24-C4-R0

ATS-HE24-C4-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH ONE 24V DC F

5

ATS-HE22-C3-R0

ATS-HE22-C3-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH ONE 12V DC F

1

ATS-HE20-C4-R0

ATS-HE20-C4-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH ONE 24V DC F

4

ATS-HE20-C5-R0

ATS-HE20-C5-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH ONE 24V DC F

1

120458

120458

Wakefield-Vette

COLD PLATE HEAT SINK EXPOSED

23

9666070

9666070

JULABO

FL7006 CHILLER, 7KW, 230V/3PPE

2

ATS-HE23-C1-R0

ATS-HE23-C1-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER 17.5X9X2.5"

10

9666110

9666110

JULABO

FL11006 CHILLER, 11KW, 230V/3PPE

2

ATS-HE21-C6-R0

ATS-HE21-C6-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH TWO 48V DC F

2

Thermal - Liquid Cooling, Heating

1. Overview

Liquid cooling and heating systems are thermal management solutions that use liquid media to transfer heat in electronic, industrial, and mechanical systems. These systems maintain optimal operating temperatures for components by absorbing, transporting, and dissipating heat (cooling) or providing controlled thermal energy (heating). Their importance has grown with increasing power densities in data centers, electric vehicles, and high-performance computing, where traditional air cooling reaches limitations.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Direct-to-Chip Liquid CoolingTargets specific heat sources with cold plates or microchannelsCPU/GPU cooling in servers
Immersion CoolingSubmerges components in dielectric coolantDatacenter server racks
Chiller-Based SystemsUses refrigeration cycles with heat exchangersIndustrial machinery cooling
Heating CirculatorsProvides precise temperature control through liquid heatingMedical device thermal calibration

3. Structure and Components

Typical systems include: - Heat exchangers (cold plates, radiators) - Circulation pumps for liquid movement - Fluid reservoirs with level/pressure monitoring - Thermal interface materials (TIMs) - Temperature sensors and control valves - Corrosion-resistant tubing with quick-disconnect fittings Modern designs often integrate smart controllers for dynamic performance adjustment.

4. Key Technical Specifications

ParameterImportanceTypical Range
Cooling CapacityDetermines maximum heat load removal1-150 kW
Temperature StabilityCritical for sensitive electronics 0.5 C
Flow RateAffects thermal response speed1-20 L/min
Pressure DropImpacts pump selection and efficiency0.5-5 bar
Material CompatibilityPrevents corrosion and leaksCopper, stainless steel, plastics

5. Application Areas

Key industries include: - Data Centers: Liquid-cooled server racks - Automotive: EV battery thermal management - Industrial: Laser cutting machine cooling - Healthcare: MRI scanner temperature control - Renewables: Solar inverter cooling systems

6. Leading Manufacturers

ManufacturerRepresentative ProductUnique Features
AsetekRapid Rack CDUModular datacenter cooling
CoolIT SystemsDLC Direct-to-ChipSealed cold plate technology
DanfossORC TurbostackHigh-efficiency heat recovery
Parker HannifinThermal LoopSpacecraft thermal control

7. Selection Recommendations

Key considerations: - Heat load profile and peak thermal requirements - Space constraints (footprint and height limitations) - Fluid compatibility with existing systems - Maintenance accessibility and service intervals - Energy efficiency (PUE for data centers) - Redundancy requirements for critical systems - Total cost of ownership (TCO) over 5-10 years

8. Industry Trends

Emerging developments include: - Adoption of two-phase immersion cooling in hyperscale data centers - Integration of AI-driven thermal optimization algorithms - Development of nanofluids for enhanced heat transfer - Standardization of liquid cooling interfaces (e.g., OCP standards) - Increased use in EV charging stations (350kW+ fast chargers) - Growth of liquid cooling in 5G base stations and edge computing

RFQ BOM Call Skype Email