Thermal - Liquid Cooling, Heating

Image Part Number Description / PDF Quantity Rfq
9421852

9421852

JULABO

PRESTO W85, REFRIG/HEAT CIRC

1

HPLC-10

HPLC-10

Wakefield-Vette

RECIRC CHILLER 115VAC 1700W

3

ATS-HE25-C3-R0

ATS-HE25-C3-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH TWO 12V DC F

0

385736-001

385736-001

Laird Thermal Systems

RECIRC CHILLER 2.9LPM 149W 4.7A

0

120456

120456

Wakefield-Vette

COLD PLATE HEAT SINK EXPOSED

23

9352755N

9352755N

JULABO

FP55-SL REFIG/HEAT CIRC

2

ATS-HE21-C2-R0

ATS-HE21-C2-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH TWO 12V DC F

4

385760-001

385760-001

Laird Thermal Systems

RECIRC CHILLR/HEATER 3.3LPM 290W

1

ATS-CHILL600V

ATS-CHILL600V

Advanced Thermal Solutions, Inc.

RECIRC CHILLER 15LPM 600W

1

ATS-CP-1002-DIY

ATS-CP-1002-DIY

Advanced Thermal Solutions, Inc.

MINI CHANNEL COLD PLATE

0

120962

120962

Wakefield-Vette

COLD PLATE HEAT SINK BURIED

5

9630100

9630100

JULABO

AWC100 AIR TO WATER COOLER

5

ATS-CHILLIM402V

ATS-CHILLIM402V

Advanced Thermal Solutions, Inc.

IMMERSION CHILLER 220V 780W 10A

0

180-10-12C

180-10-12C

Wakefield-Vette

COLD PLATE HEAT SINK 0.041C/W

0

9420300

9420300

JULABO

PRESTO A30, REFRIG/HEAT CIRC

1

ATS-HE26-C6-R0

ATS-HE26-C6-R0

Advanced Thermal Solutions, Inc.

HEAT EXCHANGER WITH FOUR 48V DC

0

385911-015

385911-015

Laird Thermal Systems

NRC2400-A1-20-ST1

2

9421552

9421552

JULABO

PRESTO W55, REFRIG/HEAT CIRC

2

180-11-6C

180-11-6C

Wakefield-Vette

COLD PLATE HEAT SINK 0.084C/W

0

ATS-CP-1000-DIY

ATS-CP-1000-DIY

Advanced Thermal Solutions, Inc.

MINI CHANNEL COLD PLATE

12

Thermal - Liquid Cooling, Heating

1. Overview

Liquid cooling and heating systems are thermal management solutions that use liquid media to transfer heat in electronic, industrial, and mechanical systems. These systems maintain optimal operating temperatures for components by absorbing, transporting, and dissipating heat (cooling) or providing controlled thermal energy (heating). Their importance has grown with increasing power densities in data centers, electric vehicles, and high-performance computing, where traditional air cooling reaches limitations.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Direct-to-Chip Liquid CoolingTargets specific heat sources with cold plates or microchannelsCPU/GPU cooling in servers
Immersion CoolingSubmerges components in dielectric coolantDatacenter server racks
Chiller-Based SystemsUses refrigeration cycles with heat exchangersIndustrial machinery cooling
Heating CirculatorsProvides precise temperature control through liquid heatingMedical device thermal calibration

3. Structure and Components

Typical systems include: - Heat exchangers (cold plates, radiators) - Circulation pumps for liquid movement - Fluid reservoirs with level/pressure monitoring - Thermal interface materials (TIMs) - Temperature sensors and control valves - Corrosion-resistant tubing with quick-disconnect fittings Modern designs often integrate smart controllers for dynamic performance adjustment.

4. Key Technical Specifications

ParameterImportanceTypical Range
Cooling CapacityDetermines maximum heat load removal1-150 kW
Temperature StabilityCritical for sensitive electronics 0.5 C
Flow RateAffects thermal response speed1-20 L/min
Pressure DropImpacts pump selection and efficiency0.5-5 bar
Material CompatibilityPrevents corrosion and leaksCopper, stainless steel, plastics

5. Application Areas

Key industries include: - Data Centers: Liquid-cooled server racks - Automotive: EV battery thermal management - Industrial: Laser cutting machine cooling - Healthcare: MRI scanner temperature control - Renewables: Solar inverter cooling systems

6. Leading Manufacturers

ManufacturerRepresentative ProductUnique Features
AsetekRapid Rack CDUModular datacenter cooling
CoolIT SystemsDLC Direct-to-ChipSealed cold plate technology
DanfossORC TurbostackHigh-efficiency heat recovery
Parker HannifinThermal LoopSpacecraft thermal control

7. Selection Recommendations

Key considerations: - Heat load profile and peak thermal requirements - Space constraints (footprint and height limitations) - Fluid compatibility with existing systems - Maintenance accessibility and service intervals - Energy efficiency (PUE for data centers) - Redundancy requirements for critical systems - Total cost of ownership (TCO) over 5-10 years

8. Industry Trends

Emerging developments include: - Adoption of two-phase immersion cooling in hyperscale data centers - Integration of AI-driven thermal optimization algorithms - Development of nanofluids for enhanced heat transfer - Standardization of liquid cooling interfaces (e.g., OCP standards) - Increased use in EV charging stations (350kW+ fast chargers) - Growth of liquid cooling in 5G base stations and edge computing