AC Fans

Image Part Number Description / PDF Quantity Rfq
R2E175-AC77-15

R2E175-AC77-15

ebm-papst Inc.

MOTORIZED IMPELLER

7

55462.19750

55462.19750

ebm-papst Inc.

HOT AIR FANS / BLOWERS

2163

4650N

4650N

ebm-papst Inc.

FAN AXIAL 119X38MM 230VAC TERM

121

W2S130-AB03-21

W2S130-AB03-21

ebm-papst Inc.

FAN AXIAL

33

S2E250-AE31-08

S2E250-AE31-08

ebm-papst Inc.

FAN AXIAL

66

4850N

4850N

ebm-papst Inc.

FAN AXIAL 119X38MM 230VAC TERM

8

W2S130-AB03-11

W2S130-AB03-11

ebm-papst Inc.

FAN AXIAL

9

A2E170-AF23-11

A2E170-AF23-11

ebm-papst Inc.

AC AXIAL FAN

4

R4E310-AO12-10

R4E310-AO12-10

ebm-papst Inc.

MOTORIZED IMPELLER

71

D2E146-CD51-09

D2E146-CD51-09

ebm-papst Inc.

BLOWER

85

FE1Q-115-060-02

FE1Q-115-060-02

ebm-papst Inc.

FAN BLWR CF 380X88MM BALL 115VAC

84

W3G250-HK35-11

W3G250-HK35-11

ebm-papst Inc.

FAN AXIAL 115V 280X80MM 1120CFM

0

A2E250-AE65-01

A2E250-AE65-01

ebm-papst Inc.

AC AXIAL FAN

0

R2E175-AC77-05

R2E175-AC77-05

ebm-papst Inc.

MOTORIZED IMPELLER

0

R2E250-AW50-05

R2E250-AW50-05

ebm-papst Inc.

MOTORIZED IMPELLER

72

R4E400-AP15-10

R4E400-AP15-10

ebm-papst Inc.

MOTORIZED IMPELLER

22

A2E200-AF02-01

A2E200-AF02-01

ebm-papst Inc.

AC AXIAL FAN

6

R2S175-AA07-39

R2S175-AA07-39

ebm-papst Inc.

MOTORIZED IMPELLER

68

4600N-466

4600N-466

ebm-papst Inc.

FAN AXIAL 119X38MM 115VAC

22

G2E108-AA01-01

G2E108-AA01-01

ebm-papst Inc.

MOTORIZED IMPELLER

5

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction