AC Fans

Image Part Number Description / PDF Quantity Rfq
W2E208-BA20-51

W2E208-BA20-51

ebm-papst Inc.

FAN AXIAL 260X80MM 230VAC TERM

18

5606S

5606S

ebm-papst Inc.

FAN AXIAL 135X38MM 115VAC TERM

154

ACI4400/2HHP

ACI4400/2HHP

ebm-papst Inc.

FAN AXIAL 119X38MM 100-240VAC

80

9906M

9906M

ebm-papst Inc.

FAN AXIAL 119X25MM 115VAC TERM

3725

W2E200-CH38-70

W2E200-CH38-70

ebm-papst Inc.

FAN AXIAL 280X80MM 230VAC WIRE

0

G2E140-AC13-42

G2E140-AC13-42

ebm-papst Inc.

BLOWER CENT 226X130MM 115VAC

8

D2E146-AP47-22

D2E146-AP47-22

ebm-papst Inc.

BLOWER

0

W2E250-HJ32-01

W2E250-HJ32-01

ebm-papst Inc.

FAN AXIAL 280X80MM BALL 115VAC

7640

D2E097-BI56-83

D2E097-BI56-83

ebm-papst Inc.

FAN BLWR CENT BALL 230VAC WIRE

0

55444.10000

55444.10000

ebm-papst Inc.

FAN BLOWER CF 100X74MM 115VAC

0

4606ZW

4606ZW

ebm-papst Inc.

FAN AXIAL 119X38MM 115VAC WIRE

337

55416.30250

55416.30250

ebm-papst Inc.

FAN BLWR CF 240X108MM 115VAC

104

9956

9956

ebm-papst Inc.

FAN AXIAL 119X25MM 230VAC TERM

346

R2E225-BE47-09

R2E225-BE47-09

ebm-papst Inc.

FAN IMP MTRZD 225X88MM 230VAC

30

4656Z

4656Z

ebm-papst Inc.

FAN AXIAL 119X38MM 230VAC TERM

109225

R2E225-BE51-09

R2E225-BE51-09

ebm-papst Inc.

FAN IMP MTRZD 225X107MM 115VAC

301

55412.70305

55412.70305

ebm-papst Inc.

FAN BLWR CF 300X96MM 115VAC TERM

0

W2E250-HJ28-09

W2E250-HJ28-09

ebm-papst Inc.

FAN AXIAL 230VAC 280X80MM

0

G2E108-AA05-44

G2E108-AA05-44

ebm-papst Inc.

FAN BLWR CENT 159X115MM 115VAC

16

D2E097-CB01-02

D2E097-CB01-02

ebm-papst Inc.

FAN BLWR CENT 144X140MM 230VAC

10

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email
Top