AC Fans

Image Part Number Description / PDF Quantity Rfq
A2S130-AA03-22

A2S130-AA03-22

ebm-papst Inc.

AC AXIAL FAN

77

G2E133-DN77-01

G2E133-DN77-01

ebm-papst Inc.

MOTORIZED IMPELLER

89

55416.29045

55416.29045

ebm-papst Inc.

FAN BLWR CF 2X182X489MM 115VAC

450

W2E200-CI38-01

W2E200-CI38-01

ebm-papst Inc.

FAN AXIAL 280X80MM 230VAC

0

8880TV

8880TV

ebm-papst Inc.

FAN AXIAL 76X37MM 230VAC WIRE

0

R2E225-BD92-36

R2E225-BD92-36

ebm-papst Inc.

MOTORIZED IMPELLER

6

RG125-19/56

RG125-19/56

ebm-papst Inc.

FAN BLWR FLATPAK 180X40MM 230VAC

25

RL90-18/06

RL90-18/06

ebm-papst Inc.

FAN BLWR FLATPAK 121X37MM 115VAC

140

D2E133-AM47-A3

D2E133-AM47-A3

ebm-papst Inc.

FAN BLWR CENT 172X254MM 230VAC

12

A4E450-AP01-01

A4E450-AP01-01

ebm-papst Inc.

AC AXIAL FAN

11

W2S130-AA25-01

W2S130-AA25-01

ebm-papst Inc.

FAN AXIAL 150X55MM 115VAC WIRE

52

W1G172-EC95-01

W1G172-EC95-01

ebm-papst Inc.

FAN AXIAL

92

4650Z-876

4650Z-876

ebm-papst Inc.

FAN AXIAL 119X38MM 230VAC

915

W2S130-AA03-90

W2S130-AA03-90

ebm-papst Inc.

FAN AXIAL

10

A2D250-AA02-01

A2D250-AA02-01

ebm-papst Inc.

AC AXIAL FAN

72

W2S130-AA03-87

W2S130-AA03-87

ebm-papst Inc.

FAN AXIAL 172X55MM 230VAC WIRE

20

W2S130-AA25-65

W2S130-AA25-65

ebm-papst Inc.

FAN AXIAL 150X55MM 115VAC WIRE

9

W2S130-AA03-44

W2S130-AA03-44

ebm-papst Inc.

FAN AXIAL 150X55MM 230VAC TERM

7

5656S

5656S

ebm-papst Inc.

FAN AXIAL 135X38MM 230VAC TERM

22

3656

3656

ebm-papst Inc.

FAN AXIAL 92X38MM 230VAC WIRE

98

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email
Top