AC Fans

Image Part Number Description / PDF Quantity Rfq
55444.50000

55444.50000

ebm-papst Inc.

FAN BLOWER CF 300X74MM 115VAC

157

D2E133-AB21-33

D2E133-AB21-33

ebm-papst Inc.

FAN BLWR CENT 172X254MM 115VAC

8

A2E200-AF02-54

A2E200-AF02-54

ebm-papst Inc.

AC AXIAL FAN

0

4656NU

4656NU

ebm-papst Inc.

FAN AXIAL 119X38MM 230VAC

0

55462.40750

55462.40750

ebm-papst Inc.

HOT AIR FANS / BLOWERS

4323

55416.17090

55416.17090

ebm-papst Inc.

FAN BLOWER CF 122X108MM 115VAC

0

D2E133-AM47-01

D2E133-AM47-01

ebm-papst Inc.

FAN BLWR CENT 171X215MM 230VAC

1

R2E140-AL40-05

R2E140-AL40-05

ebm-papst Inc.

MOTORIZED IMPELLER

47

R2E250-AL05-16

R2E250-AL05-16

ebm-papst Inc.

MOTORIZED IMPELLER

38

ACI4420H

ACI4420H

ebm-papst Inc.

FAN 120/230VAC 119X38MM 94CFM

11

4530N

4530N

ebm-papst Inc.

FAN AXIAL 119X38MM 115VAC TERM

16

W2D250-CA06-52

W2D250-CA06-52

ebm-papst Inc.

FAN AXIAL

0

A2D250-AH02-01

A2D250-AH02-01

ebm-papst Inc.

AC AXIAL FAN

19

R2S150-AA08-29

R2S150-AA08-29

ebm-papst Inc.

MOTORIZED IMPELLER

3

D4E133-DL01-H9

D4E133-DL01-H9

ebm-papst Inc.

BLOWER

5

55442.55250

55442.55250

ebm-papst Inc.

AC FAN BLOWER CROSSFLOW

4103

R4E225-AI01-10

R4E225-AI01-10

ebm-papst Inc.

FAN IMP MTRZD 225X63MM 230VAC

11

W3G250-HH53-03

W3G250-HH53-03

ebm-papst Inc.

FAN AXIAL 115V 280X80MM 846CFM

7

55462.19490

55462.19490

ebm-papst Inc.

HOT AIR FANS / BLOWERS

53

G2E160-AY47-01

G2E160-AY47-01

ebm-papst Inc.

BLOWER ALUMINUM 230VAC

2

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email