Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
3210568

3210568

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

35

3004016

3004016

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

39112150

3210583

3210583

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

162

2794916

2794916

Phoenix Contact

CONN TERM BLK FEED THRU 10-26AWG

0

3206241

3206241

Phoenix Contact

CONN TERM BLK FEED THRU 16-24AWG

16

3209015

3209015

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

25841050

3036356

3036356

Phoenix Contact

CONN TERM BLK DISCONN 12-28AWG

50

3031131

3031131

Phoenix Contact

CONN TERM BLK FEED THRU 14-26AWG

20

0441025

0441025

Phoenix Contact

CONN TERM BLK GROUND 12-30AWG

450200

3209031

3209031

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

19500

3046294

3046294

Phoenix Contact

CONN TERM BLK FEED THRU 12-24AWG

8750

3005112

3005112

Phoenix Contact

CONN TERM BLK DISCONNECT 6-24AWG

0

3007123

3007123

Phoenix Contact

CONN TERM BLK GROUND 10-26AWG

2259

3215915

3215915

Phoenix Contact

CONN TERM BLK GROUND 4-16 AWG

38

3046003

3046003

Phoenix Contact

CONN TERM BLK DISCONN 10-26AWG

2

3038493

3038493

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

0

3031364

3031364

Phoenix Contact

CONN TERM BLK FEED THRU 10-28AWG

178220300

1086471

1086471

Phoenix Contact

TERM BLOCK HIGH-CURRENT

12

3210253

3210253

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

47500

3100305

3100305

Phoenix Contact

CONN TERM BLK FEED THRU 14-30AWG

62027250

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top