Terminal Blocks - Din Rail, Channel

Image Part Number Description / PDF Quantity Rfq
2717016

2717016

Phoenix Contact

CONN TERM BLK FEED THRU 14-30AWG

0

3211793

3211793

Phoenix Contact

CONN TERM BLK FEED THRU 10-24AWG

0

3209617

3209617

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

1350

3281176

3281176

Phoenix Contact

TERM BLOCK FEE THROUGH 6-20AWG

181

3036314

3036314

Phoenix Contact

CONN TERM BLK FEED THRU 12-28AWG

0

2775456

2775456

Phoenix Contact

CONN TERM BLK GROUND 12-30AWG

45

3034044

3034044

Phoenix Contact

CONN TERM BLK GROUND 12-24AWG

0

0311126

0311126

Phoenix Contact

CONN TERM BLK DISCONNECT 8-26AWG

1

3210351

3210351

Phoenix Contact

CONN TERM BLK DISCONN 16-26AWG

35

3209578

3209578

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

4208

3050044

3050044

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

0

3210352

3210352

Phoenix Contact

CONN TERM BLK DISCONN 16-26AWG

0

3036013

3036013

Phoenix Contact

CONN TERM BLK GROUND 14-26AWG

40

0309112

0309112

Phoenix Contact

CONN TERM BLK DISCONNECT 6-20AWG

0

3044597

3044597

Phoenix Contact

CONN TERM BLK GROUND 10-26AWG

86710350

3049110

3049110

Phoenix Contact

CONN TERM BLK FEED THRU 14-26AWG

14

0441041

0441041

Phoenix Contact

CONN TERM BLK GROUND 4/0-2AWG

2123

3210251

3210251

Phoenix Contact

CONN TERM BLK DISCONN 12-26AWG

0

3000540

3000540

Phoenix Contact

CONN TERM BLK DISCONN 12-24AWG

178150

3214424

3214424

Phoenix Contact

CONN TERM BLK FEED THRU 12-26AWG

3116750

Terminal Blocks - Din Rail, Channel

1. Overview

DIN Rail and Channel Terminal Blocks are modular electrical connectors used to secure and transmit electrical signals or power between wires and devices. Designed to mount on standardized DIN rails (EN 50022) or channel rails, these components enable efficient wiring organization in industrial and commercial systems. Their importance lies in simplifying complex electrical installations, enhancing maintainability, and ensuring reliable connectivity in critical infrastructure.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Screw-Type DIN Rail Terminal BlocksUses screw clamping for secure wire connections; supports high current ratingsIndustrial control panels, HVAC systems
Spring-Clamp Terminal BlocksTool-free push-in wiring for fast installation; vibration-resistantAutomation systems, railway signaling
PCB Mount Terminal BlocksDirect printed circuit board integration; compact designTelecom equipment, medical devices
Channel Rail Terminal BlocksDesigned for C-shaped channel rails; modular expandabilityPower distribution cabinets, renewable energy systems

3. Structure and Components

Typical construction includes:

  • Conductive Elements: Copper alloy or brass contacts with tin/silver plating for corrosion resistance
  • Insulation Housing: Flame-retardant thermoplastic (UL 94 V-0 rated)
  • Mounting Mechanism: Snap-in clips for DIN rail (35mm standard) or channel rail compatibility
  • Wire Connection System: Screw terminals (M3-M4), spring clamps, or cage clamps

4. Key Technical Parameters

ParameterTypical RangeImportance
Rated Current10A - 100ADetermines power transmission capacity
Rated Voltage250V - 1000VDefines electrical insulation requirements
Wire Size Compatibility0.14mm - 300mm Matches with conductor dimensions
Insulation Resistance>1000M Ensures safety and signal integrity
Operating Temperature-20 C to +70 CMaterial performance under thermal stress

5. Application Fields

  • Industrial Automation: PLC control cabinets, motor drives
  • Energy Systems: Solar inverters, wind turbine junction boxes
  • Building Infrastructure: Smart lighting control systems
  • Rail Transport: Train power distribution panels

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPT 10-1.5/HC SeriesModular design with cross-connection capability
Weidm llerOMNIMATE PCB Terminal BlocksHigh-density PCB connectivity
Schneider ElectricEasy Connect DIN Rail BlocksIP20 protection rating, color-coded wiring
TE ConnectivityDIN-A-MITE SeriesCompact size with 6kV impulse withstand

7. Selection Guidelines

Key considerations:

  • Match current/voltage ratings with system requirements
  • Choose connection type based on maintenance needs (screw for high reliability, spring for quick changes)
  • Verify wire gauge compatibility
  • Consider environmental factors (temperature, vibration, humidity)
  • Check certifications (UL, CSA, IEC 60947)

Case Study: A smart building project selected spring-clamp terminal blocks with 600V rating and IP55 housing to enable rapid maintenance while ensuring safety in electrical rooms.

8. Industry Trends

  • Miniaturization: 30% reduction in standard DIN rail block width (e.g., 6.2mm vs. 8.4mm)
  • Smart Integration: Built-in current sensors and IoT connectivity
  • Material Innovation: Halogen-free flame retardant materials
  • Standardization: Global adoption of IEC 61535 for safe low-voltage connections
RFQ BOM Call Skype Email
Top