Terminal Blocks - Adapters

Image Part Number Description / PDF Quantity Rfq
1360260000

1360260000

Weidmuller

SLA COUPLING BLOCK 10 OG

0

9446900000

9446900000

Weidmuller

RS 16EC-O-D 24-48V H/V

0

0586661001

0586661001

Weidmuller

HOLDER CARD EDGE SKH 31S

0

0275320000

0275320000

Weidmuller

MKL 3/6 HORZ TAB 6POS BRN

0

1342760000

1342760000

Weidmuller

SLA COUPLING BLOCK 4 OG

0

993109

993109

Weidmuller

DM-AY/B MITSU OUTPUT DT MT

0

1359660000

1359660000

Weidmuller

SLA COUPLING BLOCK 2 OG

0

993108

993108

Weidmuller

DM-AX/B MITSU INPUT DT MT

0

8174830000

8174830000

Weidmuller

SKH2 D32 LPA1 PLUG IN CONN

0

943907

943907

Weidmuller

RS-SD 50FB/RS70/V

0

943138

943138

Weidmuller

RS-MSO 34/LP2NKNPC

0

993106

993106

Weidmuller

DM-AX/A MITSU INPUT DT MT

0

0241360000

0241360000

Weidmuller

TERM MK 2/12 12POS W/HZ TAB PA

0

9446920000

9446920000

Weidmuller

RS 16E-DO 230V H/V

0

0587060000

0587060000

Weidmuller

HOLDER CARD EDGE SKHF 48S

0

990283

990283

Weidmuller

RS-FCN40S-G4 FUJITSU INTERFA

0

9915490000

9915490000

Weidmuller

MODULE OUTLET AC DUPLEX

0

990013

990013

Weidmuller

RS-FCN-40B CBL INTERFACE

0

990264

990264

Weidmuller

RS-MR 50B-L4 CBL INTERFACE

0

1613220000

1613220000

Weidmuller

HEADER COUPLER 5.08MM 21POS BK

0

Terminal Blocks - Adapters

1. Overview

Terminal blocks and adapters are modular electronic components designed to establish secure electrical connections between wires, printed circuit boards (PCBs), or systems. These devices ensure reliable signal transmission, power distribution, and system modularity across diverse applications. Their importance in modern technology lies in enabling flexible wiring configurations, simplifying maintenance, and ensuring compatibility between disparate electrical systems.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Board-to-Board AdaptersDirect PCB interconnection without wires, high-density pin layoutsServers, industrial control panels
Wire-to-Board AdaptersConnects discrete wires to PCBs, screw/clamp termination optionsAutomation equipment, HVAC systems
Modular Terminal BlocksCustomizable with fuses, circuit breakers, or signal conditioningFactory automation, renewable energy systems
High-Voltage AdaptersExtended creepage distances, reinforced insulationPower distribution units, medical equipment
RF/Coaxial AdaptersImpedance-matched designs for high-frequency signalsTelecom infrastructure, test equipment

3. Structure & Components

Typical terminal blocks and adapters consist of: - Dielectric Housing: Thermoplastic (PA66, PBT) or metal alloys with UL94 V-0 flammability rating - Contact Elements: Phosphor bronze or beryllium copper with plating (gold, tin, silver) - Termination Mechanism: Screw terminals (M2-M6), spring clamps, or IDC (Insulation Displacement Contact) - Locking Features: Mechanical latches, anti-vibration screws, or push-pull coupling

4. Key Technical Parameters

ParameterTypical RangeImportance
Current Rating0.1A - 100ADetermines power handling capacity
Voltage Rating50V - 1500VEnsures dielectric strength
Contact Resistance1-20m Impacts signal integrity
Insulation Resistance100M - 10G Prevents leakage currents
Operating Temperature-60 C - +150 CMaterial stability indicator
IP RatingIP20 - IP68Environmental protection level

5. Application Fields

  • Industrial Automation: PLC I/O modules, motor drives
  • Telecommunications: Base station equipment, fiber distribution hubs
  • Renewable Energy: Solar inverters, wind turbine control systems
  • Transportation: EV charging stations, rail signaling systems
  • Medical Equipment: Diagnostic imaging devices, patient monitoring systems

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
Phoenix ContactPTFIX seriesPush-in wire connection, 8kV surge protection
TE ConnectivityMicroSpeed Plus0.8mm pitch, 10Gbps data rate
Wago285 SeriesCAGE CLAMP technology, vibration-resistant
MolexMX150Hybrid power/signal transmission
Weidm llerOMNIMATE PCBUL/CSA/IEC certifications, 24AWG-10AWG range

7. Selection Guidelines

Consider the following factors during selection: - Electrical requirements (current/voltage levels) - Environmental conditions (temperature, humidity, vibration) - Space constraints and mounting orientation - Compatibility with existing wiring/cabling infrastructure - Maintenance requirements and tooling needs - Cost-performance balance for production volumes

8. Industry Trends Analysis

Key developments shaping the market: - Miniaturization for compact IoT devices (sub-1.0mm pitch connectors) - Increased demand for high-speed data interfaces (USB4, PCIe 5.0) - Integration with smart diagnostics (built-in current/voltage sensors) - Adoption of eco-friendly materials (halogen-free polymers) - Growth in modular design approaches for rapid system reconfiguration - Enhanced EMI/RFI shielding for 5G and automotive applications

RFQ BOM Call Skype Email
Top