Heavy Duty Connectors - Frames

Image Part Number Description / PDF Quantity Rfq
09140100371

09140100371

HARTING

10B MODULAR HINGED FRAME PLUS (S

121

1417403

1417403

Phoenix Contact

FRAME HINGED FOR 2MOD

98615

T2079104101-000

T2079104101-000

TE Connectivity AMP Connectors

H10A-T1-M

155

09300241701

09300241701

HARTING

FRAME PANEL MOUNTING SZ24B

5

1182085

1182085

Phoenix Contact

FRAME MODULAR SNAP-IN

30549

C146S24001G8

C146S24001G8

Tuchel / Amphenol

FRAME FIXED FMALE SZE24 FOR 7MOD

0

09300161701

09300161701

HARTING

HAN 16 B DOCKING FRAME

4

1852914

1852914

Phoenix Contact

FRAME ASSEMBLY SZ3 FOR 4MOD

3

T2071164101-000

T2071164101-000

TE Connectivity AMP Connectors

H16BP-T4-M DOCKING FRAME_FLOATIN

49

09140240371

09140240371

HARTING

24B MODULAR HINGED FRAME PLUS (S

0

1428920000

1428920000

Weidmuller

FRAME FOR INDUSTRIAL CONNECTOR,

227

09300169301

09300169301

HARTING

16B BULKHEAD REAR FIT HOUSING FR

49

09140161701

09140161701

HARTING

FRAME PANEL MOUNTING FOR 4MOD

9

1983880000

1983880000

Weidmuller

HDC CFM 16 5F

4322

1417398

1417398

Phoenix Contact

FRAME HINGED FOR 2MOD

37

T2071104101-000

T2071104101-000

TE Connectivity AMP Connectors

H10BP-T3-M DOCKING FRAME_FLOATIN

76

0587210010

0587210010

Woodhead - Molex

FRAME PANEL MOUNTING TYPE A

60

1081570000

1081570000

Weidmuller

COUNTER FRAME SZ6

0

09140240361

09140240361

HARTING

24B MODULAR HINGED FRAME PLUS (S

51

09140100361

09140100361

HARTING

10B MODULAR HINGED FRAME PLUS (S

97

Heavy Duty Connectors - Frames

1. Overview

Heavy Duty Connectors - Frames are robust mechanical structures designed to support and protect high-current or high-voltage electrical connections in demanding environments. These frames serve as critical components in industrial systems, ensuring reliable power transmission and signal integrity while withstanding mechanical stress, temperature extremes, and environmental contaminants. Their importance spans across automation, energy infrastructure, and transportation sectors where failure prevention is paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Modular Frame SystemsCustomizable slot configurations, tool-less assemblyAutomated production lines
Panel Mount FramesFront-access design, integrated strain reliefControl cabinets in chemical plants
Weatherproof FramesIP67+ sealing, corrosion-resistant coatingsOutdoor power distribution units
High-Voltage FramesExtended creepage distances, arc-resistant materialsRailway traction systems

3. Structure and Components

Typical frames consist of: - Aluminum Alloy Housing: Provides structural integrity with weight efficiency - Copper Alloy Conductors: Ensures low-resistance electrical paths ( 98% conductivity) - Polyamide Insulation: Maintains dielectric strength up to 8kV - Mechanical Locking System: Anti-vibration latches meeting MIL-STD-810G - Thermal Management Fins: Dissipates heat at current loads >200A

4. Key Technical Specifications

ParameterValue RangeImportance
Current Rating100-5000ADetermines power transmission capacity
Voltage RangeAC 50V-1500V / DC 50V-2000VSafety and insulation requirements
IP RatingIP20-IP69KEnvironmental protection level
Contact Resistance 0.5m Influences energy efficiency
Operating Temperature-40 C to +150 CMaterial stability indicator

5. Application Fields

  • Industrial Automation: Robotic welding systems, CNC machine tooling
  • Renewable Energy: Wind turbine converters, solar inverter arrays
  • Transportation: Electric vehicle charging stations, locomotive power systems
  • Heavy Machinery: Mining equipment control panels, construction vehicle hydraulics

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesTechnical Highlights
TE ConnectivityDEUTSCH HD Frame Series1500V isolation, -55 C cold resistance
Amphenol IndustrialPowerlok HD Frames3000A capacity, quick-mate design
Phoenix ContactHeavycon SystemModular hybrid power/signal integration

7. Selection Recommendations

Key considerations include: - Electrical Requirements: Match current/voltage ratings with system specifications - Environmental Factors: Consider humidity, vibration, and chemical exposure - Compliance Standards: UL 1977, IEC 60998, or industry-specific certifications - Future Expansion: Select modular designs for scalability - Cost Analysis: Balance upfront investment vs. lifecycle maintenance costs

Example: For offshore wind turbine applications, specify IP68 frames with electroless nickel plating and 1500V insulation to withstand saltwater corrosion and high-voltage demands.

8. Industry Trends

Emerging developments include: - Miniaturization with enhanced current density (40% size reduction by 2027) - Smart frames integrating IoT sensors for predictive maintenance - Adoption of graphene-enhanced composites for thermal management - Increased demand for 1500V+ DC compatible designs in renewable energy - Standardization initiatives for cross-manufacturer interoperability (IEC 61984 amendments)

RFQ BOM Call Skype Email