Heavy Duty Connectors - Frames

Image Part Number Description / PDF Quantity Rfq
C146P24002G8

C146P24002G8

Tuchel / Amphenol

FRAME FIXED MALE SZE24 FOR 7MOD

0

09140241701

09140241701

HARTING

FRAME PANEL MOUNT MALE FOR 6MOD

0

C146P24001G8

C146P24001G8

Tuchel / Amphenol

FRAME FIXED MALE SZE24 FOR 7MOD

11

1212890000

1212890000

Weidmuller

FRAME PNL MNT FMALE SZ8 FOR 3MOD

0

T0924049044-100

T0924049044-100

TE Connectivity AMP Connectors

T0924049044-100

0

09140240313

09140240313

HARTING

FRAME HINGED FOR 6MOD

161

09300061701

09300061701

HARTING

FRAME PANEL MOUNTING SZ6B

0

1758480000

1758480000

Weidmuller

FRAME FIXED MALE SZ6 FOR 5MOD

335

1758460000

1758460000

Weidmuller

FRAME FIXED MALE SZ4 FOR 3MOD

4520

1428960000

1428960000

Weidmuller

FRAME FOR INDUSTRIAL CONNECTOR,

2041

1429030000

1429030000

Weidmuller

FRAME FOR INDUSTRIAL CONNECTOR,

35

09142240303

09142240303

HARTING

HINGED FRAME HMC 24B F. 6 MODULE

8

10381500

10381500

LAPP

CONN FRAME MC5 FEMALE

80

09110009963

09110009963

HARTING

FRAME FIXED SZ24HPR FOR 3MOD

3

09110009951

09110009951

HARTING

FRAME ASSY SZ6B FOR 1 MOD

2

C14610P02400015

C14610P02400015

Tuchel / Amphenol

FRAME MALE SZE24 FOR 6MOD

0

1417399

1417399

Phoenix Contact

FRAME HINGED FOR 3MOD

667

09110009941

09110009941

HARTING

FRAME 4XHC250-M (INVERS)

0

09400249913

09400249913

HARTING

FRAME ASSEMBLY MALE FOR 4MOD

0

09142240313

09142240313

HARTING

HINGED FRAME HMC 24B F. 6 MODULE

57

Heavy Duty Connectors - Frames

1. Overview

Heavy Duty Connectors - Frames are robust mechanical structures designed to support and protect high-current or high-voltage electrical connections in demanding environments. These frames serve as critical components in industrial systems, ensuring reliable power transmission and signal integrity while withstanding mechanical stress, temperature extremes, and environmental contaminants. Their importance spans across automation, energy infrastructure, and transportation sectors where failure prevention is paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Modular Frame SystemsCustomizable slot configurations, tool-less assemblyAutomated production lines
Panel Mount FramesFront-access design, integrated strain reliefControl cabinets in chemical plants
Weatherproof FramesIP67+ sealing, corrosion-resistant coatingsOutdoor power distribution units
High-Voltage FramesExtended creepage distances, arc-resistant materialsRailway traction systems

3. Structure and Components

Typical frames consist of: - Aluminum Alloy Housing: Provides structural integrity with weight efficiency - Copper Alloy Conductors: Ensures low-resistance electrical paths ( 98% conductivity) - Polyamide Insulation: Maintains dielectric strength up to 8kV - Mechanical Locking System: Anti-vibration latches meeting MIL-STD-810G - Thermal Management Fins: Dissipates heat at current loads >200A

4. Key Technical Specifications

ParameterValue RangeImportance
Current Rating100-5000ADetermines power transmission capacity
Voltage RangeAC 50V-1500V / DC 50V-2000VSafety and insulation requirements
IP RatingIP20-IP69KEnvironmental protection level
Contact Resistance 0.5m Influences energy efficiency
Operating Temperature-40 C to +150 CMaterial stability indicator

5. Application Fields

  • Industrial Automation: Robotic welding systems, CNC machine tooling
  • Renewable Energy: Wind turbine converters, solar inverter arrays
  • Transportation: Electric vehicle charging stations, locomotive power systems
  • Heavy Machinery: Mining equipment control panels, construction vehicle hydraulics

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesTechnical Highlights
TE ConnectivityDEUTSCH HD Frame Series1500V isolation, -55 C cold resistance
Amphenol IndustrialPowerlok HD Frames3000A capacity, quick-mate design
Phoenix ContactHeavycon SystemModular hybrid power/signal integration

7. Selection Recommendations

Key considerations include: - Electrical Requirements: Match current/voltage ratings with system specifications - Environmental Factors: Consider humidity, vibration, and chemical exposure - Compliance Standards: UL 1977, IEC 60998, or industry-specific certifications - Future Expansion: Select modular designs for scalability - Cost Analysis: Balance upfront investment vs. lifecycle maintenance costs

Example: For offshore wind turbine applications, specify IP68 frames with electroless nickel plating and 1500V insulation to withstand saltwater corrosion and high-voltage demands.

8. Industry Trends

Emerging developments include: - Miniaturization with enhanced current density (40% size reduction by 2027) - Smart frames integrating IoT sensors for predictive maintenance - Adoption of graphene-enhanced composites for thermal management - Increased demand for 1500V+ DC compatible designs in renewable energy - Standardization initiatives for cross-manufacturer interoperability (IEC 61984 amendments)

RFQ BOM Call Skype Email