Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
SG27

SG27

Ametherm

ICL 10 OHM 0.15% 6A 12.7MM

0

SL12 10006-03

SL12 10006-03

Ametherm

ICL 10 OHM 20% 6A 13MM

13190

SL22 30005-T

SL22 30005-T

Ametherm

ICL 30 OHM 20% 5A 22MM

1556

SL15 2R509-B

SL15 2R509-B

Ametherm

ICL 2.5 OHM 20% 9A 16MM

0

MS22 12103-B

MS22 12103-B

Ametherm

ICL 120 OHM 25% 3A 23MM

0

SL08 20002

SL08 20002

Ametherm

ICL 20 OHM 20% 2A 8MM

7404

SL22 60003-A

SL22 60003-A

Ametherm

ICL 60 OHM 25% 3A 22MM

0

SL12 5R005-B

SL12 5R005-B

Ametherm

ICL 5 OHM 20% 5A 13MM

0

SL08 5R003

SL08 5R003

Ametherm

ICL 5 OHM 20% 3A 8MM

2909

SL12 25002

SL12 25002

Ametherm

ICL 25 OHM 20% 2A 13MM

0

SL22 20007-B

SL22 20007-B

Ametherm

ICL 20 OHM 25% 7A 22MM

0

MS32 10015

MS32 10015

Ametherm

ICL 10 OHM 25% 15A 31MM

2481

SL10 5R004-B

SL10 5R004-B

Ametherm

ICL 5 OHM 20% 4A 10MM

0

MS35 20010

MS35 20010

Ametherm

ICL 20 OHM 10A 35MM

1911

MS32 20010

MS32 20010

Ametherm

ICL 20 OHM 25% 10A 31MM

4578

SL22 22102

SL22 22102

Ametherm

ICL 220 OHM 25% 2A 22MM

0

SL12 25002-A

SL12 25002-A

Ametherm

ICL 25 OHM 20% 2A 13MM

0

SL12 1R010-B

SL12 1R010-B

Ametherm

ICL 1 OHM 20% 10A 13MM

0

MM35 0R280-DIN

MM35 0R280-DIN

Ametherm

ICL 200 MOHM 25% 80A 68MM

0

SL32 0R540-B

SL32 0R540-B

Ametherm

ICL 500 MOHM 20% 40A 30MM

0

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.

RFQ BOM Call Skype Email