Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
MM35 0R560

MM35 0R560

Ametherm

ICL 500 MOHM 25% 60A 68MM

13

MS32 20008-B

MS32 20008-B

Ametherm

ICL 20 OHM 25% 8A 31MM

270

SL22 30005-B

SL22 30005-B

Ametherm

ICL 30 OHM 20% 5A 22MM

0

SL10 10002

SL10 10002

Ametherm

ICL 10 OHM 25% 2A 10MM

0

MS32 15012

MS32 15012

Ametherm

ICL 15 OHM 25% 12A 31MM

0

AS35 0R550

AS35 0R550

Ametherm

ICL 500 MOHM 25% 50A 36MM

0

SL10 4R004-A

SL10 4R004-A

Ametherm

ICL 4 OHM 20% 4A 10MM

0

SL12 5R004-B

SL12 5R004-B

Ametherm

ICL 5 OHM 20% 4A 13MM

0

SG313

SG313

Ametherm

ICL 10 OHM 15% 3A 11.43MM

0

SL12 1R308-B

SL12 1R308-B

Ametherm

ICL 1.3 OHM 20% 8A 13MM

0

MS15 15004-A

MS15 15004-A

Ametherm

ICL 15 OHM 25% 4.5A 15MM

0

SL22 50004

SL22 50004

Ametherm

ICL 50 OHM 20% 4A 22MM

3234

SL10 2R505-A

SL10 2R505-A

Ametherm

ICL 2.5 OHM 30% 5A 10MM

0

SL12 10006

SL12 10006

Ametherm

ICL 10 OHM 20% 6A 13MM

999

SL22 40005-A

SL22 40005-A

Ametherm

ICL 40 OHM 20% 5A 22MM

0

SG326

SG326

Ametherm

ICL 500 MOHM 20% 30A 31.75MM

0

SL15 12102-A

SL15 12102-A

Ametherm

ICL 120 OHM 25% 2A 15MM

0

SL12 8R003

SL12 8R003

Ametherm

ICL 8 OHM 20% 3A 13MM

389

MS22 50004

MS22 50004

Ametherm

ICL 50 OHM 25% 4A 23MM

4461

MS12 15102

MS12 15102

Ametherm

ICL 150 OHM 25% 2A 13.5MM

1456

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.

RFQ BOM Call Skype Email
Top