Fuses

Image Part Number Description / PDF Quantity Rfq
37215000001

37215000001

Wickmann / Littelfuse

FUSE BOARD MOUNT 5A 250VAC RAD

1222

0235.300MXP

0235.300MXP

Wickmann / Littelfuse

FUSE GLASS 300MA 250VAC 5X20MM

678

0315002.MXP

0315002.MXP

Wickmann / Littelfuse

FUSE GLASS 2A 250VAC 3AB 3AG

0

0230.375MXP

0230.375MXP

Wickmann / Littelfuse

FUSE GLASS 375MA 250VAC 125VDC

852

0274.062V

0274.062V

Wickmann / Littelfuse

FUSE BRD MNT 62MA 125VAC/VDC RAD

0

0215.400MXEP

0215.400MXEP

Wickmann / Littelfuse

FUSE CERAMIC 400MA 250VAC 5X20MM

0

0219.400TXAP

0219.400TXAP

Wickmann / Littelfuse

FUSE GLASS 400MA 250VAC 5X20MM

0

0454.375MR

0454.375MR

Wickmann / Littelfuse

FUSE BOARD MNT 375MA 125VAC/VDC

261

032602.8MXP

032602.8MXP

Wickmann / Littelfuse

FUSE CERM 2.8A 250VAC 125VDC 3AB

0

045203.5NRL

045203.5NRL

Wickmann / Littelfuse

FUSE BRD MNT 3.5A 125VAC/VDC SMD

0

0219004.TXAP

0219004.TXAP

Wickmann / Littelfuse

FUSE GLASS 4A 250VAC 5X20MM

0

0229002.MXP

0229002.MXP

Wickmann / Littelfuse

FUSE GLASS 2A 250VAC 125VDC 2AG

1912

0217.125HXP

0217.125HXP

Wickmann / Littelfuse

FUSE GLASS 125MA 250VAC 5X20MM

41

0312004.HXP

0312004.HXP

Wickmann / Littelfuse

FUSE GLASS 4A 250VAC 3AB 3AG

1660

0219.400MXABP

0219.400MXABP

Wickmann / Littelfuse

FUSE GLASS 400MA 250VAC 5X20MM

0

0239.200TXP

0239.200TXP

Wickmann / Littelfuse

FUSE GLASS 200MA 250VAC 5X20MM

0

0437.750WR

0437.750WR

Wickmann / Littelfuse

FUSE BOARD MOUNT 750MA 63VAC/VDC

790

0332001.MXP

0332001.MXP

Wickmann / Littelfuse

FUSE CERM 1A 250VAC 125VDC 3AB

0

37314000410

37314000410

Wickmann / Littelfuse

FUSE BOARD MOUNT 4A 250VAC RAD

950

0208003.MXEP

0208003.MXEP

Wickmann / Littelfuse

FUSE GLASS 3A 350VAC 2AG

996

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures