Fuses

Image Part Number Description / PDF Quantity Rfq
0326.800MXP

0326.800MXP

Wickmann / Littelfuse

FUSE CERAMIC 800MA 250VAC 125VDC

0

0AGU025.T

0AGU025.T

Wickmann / Littelfuse

FUSE AGU 25A 32V 5AG

9580

0324.375MXP

0324.375MXP

Wickmann / Littelfuse

FUSE CERAMIC 375MA 250VAC 125VDC

0

0312.062HXP

0312.062HXP

Wickmann / Littelfuse

FUSE GLASS 62MA 250VAC 3AB 3AG

3112

0298250.UXT

0298250.UXT

Wickmann / Littelfuse

FUSE AUTO 250A 32VDC AUTO LINK

500

0438004.WRA

0438004.WRA

Wickmann / Littelfuse

FUSE BRD MNT 4A 12VAC 32VDC 0603

149021000

0313005.HXP

0313005.HXP

Wickmann / Littelfuse

FUSE GLASS 5A 250VAC 3AB 3AG

0

0209.800MXP

0209.800MXP

Wickmann / Littelfuse

FUSE GLASS 800MA 350VAC 2AG

0

0312.062HXCCP

0312.062HXCCP

Wickmann / Littelfuse

FUSE GLASS 62MA 250VAC 3AB 3AG

0

02321.25MXEP

02321.25MXEP

Wickmann / Littelfuse

FUSE GLASS 1.25A 250VAC 5X20MM

0

0AGW005.VP

0AGW005.VP

Wickmann / Littelfuse

FUS AGW 7AG 32V 5PK CARD 5A

0

0285.500HXRP

0285.500HXRP

Wickmann / Littelfuse

FUSE CERAMIC 500MA 250VAC 5X20MM

0

026302.5MXL

026302.5MXL

Wickmann / Littelfuse

FUSE BOARD MNT 2.5A 250VAC AXIAL

1558

031201.6VXP

031201.6VXP

Wickmann / Littelfuse

FUSE GLASS 1.6A 250VAC 3AB 3AG

0

02171.25VXP

02171.25VXP

Wickmann / Littelfuse

FUSE GLASS 1.25A 250VAC 5X20MM

0

0278003.V

0278003.V

Wickmann / Littelfuse

FUSE BOARD MNT 3A 125VAC/VDC RAD

55

0218002.MXF5P

0218002.MXF5P

Wickmann / Littelfuse

FUSE GLASS 2A 250VAC 5X20MM

0

0209.750MXP

0209.750MXP

Wickmann / Littelfuse

FUSE GLASS 750MA 350VAC 2AG

0

37206300431

37206300431

Wickmann / Littelfuse

FUSE BOARD MNT 630MA 250VAC RAD

0

0299060.L

0299060.L

Wickmann / Littelfuse

FUSE AUTO 60A 32VDC BLADE

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top