Fuses

Image Part Number Description / PDF Quantity Rfq
0218.050MRET1P

0218.050MRET1P

Wickmann / Littelfuse

FUSE GLASS 50MA 250VAC 5X20MM

0

025101.5PAT1L

025101.5PAT1L

Wickmann / Littelfuse

FUSE BOARD MOUNT 1.5A 125VAC/VDC

0

0505016.MXP

0505016.MXP

Wickmann / Littelfuse

FUSE CERAMIC 16A 500VAC/VDC 3AB

2723

0672.300MXE

0672.300MXE

Wickmann / Littelfuse

FUSE GLASS 300MA 250VAC AXIAL

0

0229004.MXSP

0229004.MXSP

Wickmann / Littelfuse

FUSE GLASS 4A 125VAC/VDC 2AG

0

0312003.HXP

0312003.HXP

Wickmann / Littelfuse

FUSE GLASS 3A 250VAC 3AB 3AG

901

0279003.V

0279003.V

Wickmann / Littelfuse

FUSE BOARD MNT 3A 125VAC/VDC RAD

0

0215004.MXF11P

0215004.MXF11P

Wickmann / Littelfuse

FUSE CERAMIC 4A 250VAC 5X20MM

0

02131.25MXP

02131.25MXP

Wickmann / Littelfuse

FUSE GLASS 1.25A 250VAC 5X20MM

744

0453.250NR

0453.250NR

Wickmann / Littelfuse

FUSE BOARD MNT 250MA 125VAC/VDC

0

0332007.HXP

0332007.HXP

Wickmann / Littelfuse

FUSE CERM 7A 250VAC 125VDC 3AB

0

021602.5TXP

021602.5TXP

Wickmann / Littelfuse

FUSE CERAMIC 2.5A 250VAC 5X20MM

0

089107.5U

089107.5U

Wickmann / Littelfuse

FUSE AUTO 7.5A 58VDC BLADE MINI

274

0225007.VXUP

0225007.VXUP

Wickmann / Littelfuse

FUSE GLASS 7A 125VAC 2AG

0

37421000430

37421000430

Wickmann / Littelfuse

FUSE BOARD MNT 10A 250VAC RADIAL

0

0215008.MXGP

0215008.MXGP

Wickmann / Littelfuse

FUSE CERAMIC 8A 250VAC 5X20MM

0

0235006.VXEP

0235006.VXEP

Wickmann / Littelfuse

FUSE GLASS 6A 125VAC 5X20MM

0

0233005.MXP

0233005.MXP

Wickmann / Littelfuse

FUSE GLASS 5A 125VAC 5X20MM

250

0251007.MAT1L

0251007.MAT1L

Wickmann / Littelfuse

FUSE BRD MNT 7A 125VAC/VDC AXIAL

13000

0215.315TXP

0215.315TXP

Wickmann / Littelfuse

FUSE CERAMIC 315MA 250VAC 5X20MM

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top