Fuses

Image Part Number Description / PDF Quantity Rfq
0257030.PXAPC

0257030.PXAPC

Wickmann / Littelfuse

FUSE AUTO 30A 32VDC BLADE

52664000

0326.700HXP

0326.700HXP

Wickmann / Littelfuse

FUSE CERAMIC 700MA 250VAC 125VDC

0

SF-0402FP050F-2

SF-0402FP050F-2

J.W. Miller / Bourns

FUSE BOARD MNT 500MA 35VDC 0402

2479

TR2/C515S-5-R

TR2/C515S-5-R

PowerStor (Eaton)

FUSE GLASS 5A 125VAC 2AG

0

BK/GBB-1-R

BK/GBB-1-R

PowerStor (Eaton)

FUSE CERM 1A 250VAC/125VDC 3AB

195

S500-80-R

S500-80-R

PowerStor (Eaton)

FUSE GLASS 80MA 250VAC 5X20MM

0

0AGC003.VP

0AGC003.VP

Wickmann / Littelfuse

FUSE GLASS 3A 32VAC/VDC 5PK CARD

2025

0034.6619

0034.6619

Schurter

FUSE BRD MNT 2.5A 250VAC 125VDC

35021400

C1F 5

C1F 5

Bel Fuse, Inc.

FUSE 5.0A 125VAC FAST 1206

51

0603SFF050F/32-2

0603SFF050F/32-2

Wickmann / Littelfuse

FUSE BOARD MNT 500MA 32VDC 0603

29

PCI-5-R

PCI-5-R

PowerStor (Eaton)

FUSE BOARD MNT 5A 125VAC/400VDC

0

032602.5HXP

032602.5HXP

Wickmann / Littelfuse

FUSE CERM 2.5A 250VAC 125VDC 3AB

4500

74-4FG1A

74-4FG1A

NTE Electronics, Inc.

FUSE GLASS 1A 250VAC 2AG

480

3403.0123.24

3403.0123.24

Schurter

FUSE BOARD MOUNT 5A 125VAC 2SMD

0

0ACA-9250-TE

0ACA-9250-TE

Bel Fuse, Inc.

FUSE 25A 72VDC SLOW SMD 2410

0

0216.050TXP

0216.050TXP

Wickmann / Littelfuse

FUSE CERAMIC 50MA 250VAC 5X20MM

0

0230003.HXSP

0230003.HXSP

Wickmann / Littelfuse

FUSE GLASS 3A 250VAC/125VDC AXL

0

3403.0286.11

3403.0286.11

Schurter

FUSE BRD MNT 16A 250VAC/125VDC

2075

045201.5MRL

045201.5MRL

Wickmann / Littelfuse

FUSE BRD MNT 1.5A 125VAC/VDC SMD

13638

8020.0603

8020.0603

Schurter

FUSE CERAMIC 12A 250VAC 3AB 3AG

297

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top