Fuses

Image Part Number Description / PDF Quantity Rfq
0494002.NR

0494002.NR

Wickmann / Littelfuse

FUSE BOARD MNT 2A 32VAC/VDC 0603

4097

022403.5DRT3P

022403.5DRT3P

Wickmann / Littelfuse

FUSE GLASS 3.5A 250VAC 125VDC

0

BK1/GMA-100-R

BK1/GMA-100-R

PowerStor (Eaton)

FUSE GLASS 100MA 250VAC 5X20MM

799

0680L1000-25

0680L1000-25

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 1A

0

BK/GMA-15-R

BK/GMA-15-R

PowerStor (Eaton)

FUSE GLASS 15A 125VAC 5X20MM

1876500

37003150000

37003150000

Wickmann / Littelfuse

FUSE BOARD MNT 315MA 250VAC RAD

0

0154.250DRL

0154.250DRL

Wickmann / Littelfuse

FUSE BOARD MNT 250MA 125VAC/VDC

14

0034.5710.11

0034.5710.11

Schurter

FUSE GLASS 500MA 250VAC 5X20MM

0

80715000440

80715000440

Wickmann / Littelfuse

FUSE BOARD MOUNT 5A 300VAC RAD

0

46211250000

46211250000

Wickmann / Littelfuse

FUSE BRD MNT 1.25A 350VAC/VDC

1500

FSG-2A

FSG-2A

OptiFuse

AUTO GLASS - 13/32"X1-1/2", 2A

1878

F1206B1R00FSTR

F1206B1R00FSTR

Elco (AVX)

FUSE BOARD MOUNT 1A 63VDC 1206

3191

BK/GDA-160MA

BK/GDA-160MA

PowerStor (Eaton)

FUSE CERAMIC 160MA 250VAC 5X20MM

0

0230007.DRT2P

0230007.DRT2P

Wickmann / Littelfuse

FUSE GLASS 7A 125VAC/VDC AXIAL

0

ANT-I-30A

ANT-I-30A

OptiFuse

FUSE AUTO 30A 32VDC BLADE MICRO

1596

37404000410

37404000410

Wickmann / Littelfuse

FUSE BOARD MNT 400MA 250VAC RAD

967

AGC-V-175/1000R

AGC-V-175/1000R

PowerStor (Eaton)

BUSS SMALL DIMENSION FUSE

0

TCC-3.15A

TCC-3.15A

OptiFuse

CERAMIC-5X20MM (UL), SLOW 3.15A

1500

0229.250HXSP

0229.250HXSP

Wickmann / Littelfuse

FUSE GLASS 250MA 250VAC 125VDC

0

74-6FG2.5A

74-6FG2.5A

NTE Electronics, Inc.

FUSE GLASS 2.5A 250VAC 6X30MM

3832

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top