Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
002631006

002631006

Altech Corporation

FUSECH14X51AM8A690VAC

0

004110378

004110378

Altech Corporation

FUSENH1CGPVM125A1000VDC

0

16D27SB

16D27SB

Altech Corporation

FUSE CARTRIDGE 16A 500VAC

70

004184417

004184417

Altech Corporation

FUSENH1AMM200A690VAC KOMBI

0

004196326

004196326

Altech Corporation

FUSENH3GGM300A690VAC KOMBIISOLAT

0

004256110

004256110

Altech Corporation

FUSEHVVVTD292MM32A 10/24KVD=68ST

0

004181307

004181307

Altech Corporation

FUSENH00CGGM25A690VAC KOMBI

0

004246508

004246508

Altech Corporation

FUSEHVVVTD442MM20A 10/17.5KVD=53

0

4113804

4113804

Altech Corporation

FUSE LINK 50A IND 1200V RATE

0

004237513

004237513

Altech Corporation

FUSEHVVVTE442MM63A 6/12KVD=68STR

0

004110203

004110203

Altech Corporation

FUSENH00CDCM40A440VDC

0

002625222

002625222

Altech Corporation

FUSE CARTRIDGE 6A 1.2KVDC

0

004750236

004750236

Altech Corporation

FUSEBS38AR250A240VAC 120VDC

0

004110559

004110559

Altech Corporation

FUSE 400A 1.1KVDC INDIC

0

004362216

004362216

Altech Corporation

FUSENH0ARM160A1000VAC 200KA ACFO

0

50D33SB

50D33SB

Altech Corporation

FUSEDIAZEDSLOW BLOW (5) DIII(E33

0

004371105

004371105

Altech Corporation

FUSENH00CARS8016A690VAC 200KA AC

0

004225004

004225004

Altech Corporation

FUSEHVVVC192MM4A 3/7.2KVD=53MMST

0

004113814

004113814

Altech Corporation

FUSENH2GGM50A1200VAC TRIP INDICA

0

16C10X38SC

16C10X38SC

Altech Corporation

FUSE CARTRIDGE 16A 600VAC 5AG

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email
Top