Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
50D33FB

50D33FB

Altech Corporation

FUSEDIAZEDFAST BLOW 5 DIII(E33)5

25

200SB1C1-6

200SB1C1-6

Altech Corporation

FUSE SQUARE 200A 660VAC RECT

0

16C8X32AM

16C8X32AM

Altech Corporation

FUSE CARTRIDGE 20A 400VAC

0

004181211

004181211

Altech Corporation

FUSENH00CGGM50A500VAC KOMBI

0

004246103

004246103

Altech Corporation

FUSEHVVVTD292MM2A 10/17.5KVD=53S

0

004723214

004723214

Altech Corporation

FUSENH1GRM100A690VAC 550VDC200KA

0

002625115

002625115

Altech Corporation

FUSE CARTRIDGE 2A 1KVDC

0

004394728

004394728

Altech Corporation

FUSENH2ARS110630A690VAC 200KA AC

0

004226517

004226517

Altech Corporation

FUSEHVVVTD292MM160A 3/7.2KVD=85M

0

004255515

004255515

Altech Corporation

FUSEHVVVC537MM100A 10/24KVD=68ST

0

004721225

004721225

Altech Corporation

FUSE 40A 690VAC 550VDC

0

004176105

004176105

Altech Corporation

FUSENH4AGGM630A690VAC

0

002213001

002213001

Altech Corporation

FUSE CARTRIDGE 80A 400VAC/250VDC

0

004183311

004183311

Altech Corporation

FUSENH0GGM50A690VAC KOMBI

0

002640009

002640009

Altech Corporation

FUSECH22X58GG16A690VAC

0

004750502

004750502

Altech Corporation

FUSE 10A 690VAC 350VDC

0

004196329

004196329

Altech Corporation

FUSENH3GGM400A690VAC KOMBIISOLAT

0

004183207

004183207

Altech Corporation

FUSENH0GGM25A500VAC KOMBI

0

250NH1AR-6

250NH1AR-6

Altech Corporation

FUSE SQUARE 250A 660VAC RECT

0

004247511

004247511

Altech Corporation

FUSEHVVVTE442MM40A 10/17.5KVD=53

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email
Top