Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
GBA-1-1/2

GBA-1-1/2

PowerStor (Eaton)

FUSE CARTRIDGE 1.5A 125VAC CYL

0

GLQ-3

GLQ-3

PowerStor (Eaton)

FUSE BUSS IN-LINE 300V 3A FAST

0

GLR-2

GLR-2

PowerStor (Eaton)

FUSE IN-LINE 300V 2A CABLE WIRE

0

7.2WKNHO2 2X315

7.2WKNHO2 2X315

PowerStor (Eaton)

FUSE CARTRIDGE 200A 7.2KVAC

0

GRF-7

GRF-7

PowerStor (Eaton)

FUSE IN-LINE 300V 7A CABLE WIRE

0

BK/GLR-1J0267

BK/GLR-1J0267

PowerStor (Eaton)

FUSE CARTRIDGE 300VAC

0

GLD-10

GLD-10

PowerStor (Eaton)

FUSE INDICATING 10A 50VAC/VDC

0

BK1/TDC180-3A

BK1/TDC180-3A

PowerStor (Eaton)

FUSE CARTRIDGE 3A 240VAC 8AG

1453

BK/GRF-7

BK/GRF-7

PowerStor (Eaton)

FUSE CARTRIDGE 7A 300VAC

0

GBC-16

GBC-16

PowerStor (Eaton)

FUSE AUTOMOTIVE 16A 32VAC/VDC

40

LKC-A-5

LKC-A-5

PowerStor (Eaton)

FUSE CARTRIDGE BLADE 5A STUD MT

0

GLR-8

GLR-8

PowerStor (Eaton)

FUSE IN-LINE 300V 8A CABLE WIRE

0

BK/GMF-3

BK/GMF-3

PowerStor (Eaton)

FUSE CARTRIDGE 3A 300VAC

1004000

GMF-2

GMF-2

PowerStor (Eaton)

FUSE IN-LINE 300V 2A CABLE WIRE

10

BK/GMF-3-2/10

BK/GMF-3-2/10

PowerStor (Eaton)

FUSE CARTRIDGE 3.2A 300VAC

100

BK/TDC180-7A

BK/TDC180-7A

PowerStor (Eaton)

FUSE CARTRIDGE 7A 264VAC 8AG

0

BK/GMF-5

BK/GMF-5

PowerStor (Eaton)

FUSE CARTRIDGE 5A 300VAC

100

GMF-2-8/10

GMF-2-8/10

PowerStor (Eaton)

FUSE CARTRIDGE 2.8A 300VAC

0

GMQ-6-1/4

GMQ-6-1/4

PowerStor (Eaton)

FUSE CARTRIDGE 6.25A 300VAC

10

BK/TDC180-2A

BK/TDC180-2A

PowerStor (Eaton)

FUSE CARTRIDGE 2A 240VAC 8AG

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email
Top