Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
BK/GLR-1-1/2

BK/GLR-1-1/2

PowerStor (Eaton)

FUSE CARTRIDGE 1.5A 300VAC

90

GLR-1

GLR-1

PowerStor (Eaton)

FUSE IN-LINE 300V 1A CABLE WIRE

0

GLD-4

GLD-4

PowerStor (Eaton)

FUSE INDICATING 4A 125VAC CYL

0

CC12M15A

CC12M15A

PowerStor (Eaton)

FUSE BOARD MOUNT 15A 24VDC 1206

2790

GBC-8

GBC-8

PowerStor (Eaton)

FUSE AUTOMOTIVE 8A 32VAC/VDC

115

BK/GLQ-1/2

BK/GLQ-1/2

PowerStor (Eaton)

FUSE CARTRIDGE

0

GLQ-1

GLQ-1

PowerStor (Eaton)

FUSE BUSS IN-LINE 300V 1A FAST

0

GMQ-5

GMQ-5

PowerStor (Eaton)

FUSE IN-LINE 300V 5A CABLE WIRE

5

M-C180-5A

M-C180-5A

PowerStor (Eaton)

FUSE CRTRDGE 5A 240VAC 10X10 PK

0

GMF-1-1/4

GMF-1-1/4

PowerStor (Eaton)

FUSE CARTRIDGE 1.25A 300VAC

0

C180-10A

C180-10A

PowerStor (Eaton)

FUSE CARTRIDGE 10A 240VAC 8AG

0

GLR-7

GLR-7

PowerStor (Eaton)

FUSE IN-LINE 300V 7A CABLE WIRE

50

BK/GLQ-1-1/2

BK/GLQ-1-1/2

PowerStor (Eaton)

FUSE CARTRIDGE 1.5A 300VAC

0

GMQ-1-1/4

GMQ-1-1/4

PowerStor (Eaton)

FUSE CARTRIDGE 1.25A 300VAC

0

7.2WKNHO2 2X200

7.2WKNHO2 2X200

PowerStor (Eaton)

FUSE CARTRIDGE 200A 7.2KVAC

0

C180-2A

C180-2A

PowerStor (Eaton)

FUSE CARTRIDGE 2A 240VAC 8AG

0

GLD-2

GLD-2

PowerStor (Eaton)

FUSE INDICATING 2A 125VAC CYL

20

BK/GMQ-2-1/2

BK/GMQ-2-1/2

PowerStor (Eaton)

FUSE CARTRIDGE 2.5A 300VAC

1000

BK/GMQ-8/10

BK/GMQ-8/10

PowerStor (Eaton)

FUSE CARTRIDGE 800MA 300VAC

0

GLR-1-1/2

GLR-1-1/2

PowerStor (Eaton)

FUSE CARTRIDGE 1.5A 300VAC

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email