Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
0914989

0914989

Phoenix Contact

CIR BRKR 1.5A 250VAC 65VDC

0

5043941

5043941

Phoenix Contact

CB TMC 1 F1 200 0.1A

0

2905808

2905808

Phoenix Contact

CIRCUIT BREAKER

0

0914248

0914248

Phoenix Contact

CB TMC 1 F1 200 0.8A

0

0915357

0915357

Phoenix Contact

CIR BRKR THRM-MAG 2A LEVER

0

2905799

2905799

Phoenix Contact

CIRCUIT BREAKER

0

5652256

5652256

Phoenix Contact

CIR BRKR

0

0915412

0915412

Phoenix Contact

CIR BRKR THRM-MAG 8A LEVER

0

0914206

0914206

Phoenix Contact

CB TMC 1 F1 200 0.3A

0

0915784

0915784

Phoenix Contact

CIR BRKR THRMMAG 3A 250VAC 65VDC

0

0915475

0915475

Phoenix Contact

CIRCUIT BREAKER THRM-MAG 100MA

0

0902328

0902328

Phoenix Contact

CIR BRKR THRMMAG 1A 480VAC LEVER

0

0914728

0914728

Phoenix Contact

CIR BRKR THRM-MAG 15A 250VAC

0

0915522

0915522

Phoenix Contact

CIR BRKR 400MA 250VAC 65VDC

0

2905801

2905801

Phoenix Contact

CIRCUIT BREAKER

0

0915687

0915687

Phoenix Contact

CIR BRKR 200MA 250VAC 65VDC

0

0915438

0915438

Phoenix Contact

CIR BRKR 12A 250VAC 65VDC

0

0915823

0915823

Phoenix Contact

CIR BRKR THRMMAG 8A 250VAC 65VDC

0

0911047

0911047

Phoenix Contact

ECP 3

0

0902386

0902386

Phoenix Contact

CIR BRKR THRM-MAG 13A 480VAC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top