Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
0914552

0914552

Phoenix Contact

CIR BRKR 200MA 250VAC 65VDC

0

5652558

5652558

Phoenix Contact

RDE_UC-17S1N12F3DU35150508058

0

0915674

0915674

Phoenix Contact

CIR BRKR 16A 250VAC 65VDC

0

0914594

0914594

Phoenix Contact

CIR BRKR 600MA 250VAC 65VDC

0

0915409

0915409

Phoenix Contact

CIR BRKR THRM-MAG 6A LEVER

0

5652879

5652879

Phoenix Contact

RDE_GAEI9-KDC6-P205

0

0915289

0915289

Phoenix Contact

CIR BRKR THRM-MAG 300MA LEVER

0

0915328

0915328

Phoenix Contact

CIR BRKR THRM-MAG 800MA LEVER

0

2905810

2905810

Phoenix Contact

CIRCUIT BREAKER

0

2905811

2905811

Phoenix Contact

CIRCUIT BREAKER

0

0902438

0902438

Phoenix Contact

CIR BRKR THRM-MAG 40A 480VAC

0

0914219

0914219

Phoenix Contact

CB TMC 1 F1 200 0.4A

0

0914729

0914729

Phoenix Contact

CIR BRKR THRM-MAG 20A LEVER

0

0915742

0915742

Phoenix Contact

CIR BRKR THRMMAG 1A 250VAC 65VDC

0

0902454

0902454

Phoenix Contact

CIR BRKR THRM-MAG 63A 480VAC

0

0902276

0902276

Phoenix Contact

CIR BRKR THRM-MAG 32A 277VAC

0

2905802

2905802

Phoenix Contact

CIRCUIT BREAKER

0

0915034

0915034

Phoenix Contact

CIR BRKR THRM-MAG 25A 250VAC

0

2905809

2905809

Phoenix Contact

CIRCUIT BREAKER

0

0912019

0912019

Phoenix Contact

CIR BRKR SOLID STATE 8A 24VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure