Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9926252204

9926252204

Weidmuller

QL-2-13-DM-1-04

0

9912201309

9912201309

Weidmuller

CIRCUIT BREAKER 2A

0

9921161302

9921161302

Weidmuller

CB2211-10 W/O AUX T1 16.0A

0

9913301302

9913301302

Weidmuller

CB2213-10 W/O AUX T1 3.0A

0

9129583500

9129583500

Weidmuller

CIR BRKR 500MA 250VAC 80VDC

0

BR2C25UC

BR2C25UC

Weidmuller

CB MCB 489 2P C 25A ACDC

18

9912041302

9912041302

Weidmuller

CB2212-10 W/O AUX T1 0.4A

0

SU3C1UC

SU3C1UC

Weidmuller

CB PROTECTOR 1077 3P C 1A ACDC

127

9926291130

9926291130

Weidmuller

CIR BRKR MAG-HYDR 30A 240VAC

49

9913100003

9913100003

Weidmuller

CIR BRKR THRMMAG 1A 480VAC 65VDC

0

9912401303

9912401303

Weidmuller

CB2212-10 W/NO&NC AUX4.0A(T1

0

BR2C8UC

BR2C8UC

Weidmuller

CB MCB 489 2P C 8A ACDC

94

9926281025

9926281025

Weidmuller

CIR BRKR MAG-HYDR 25A 120VAC

0

BR3D16UC

BR3D16UC

Weidmuller

CB MCB 489 3P D 16A ACDC

13

9124273500

9124273500

Weidmuller

CIR BRKR 400MA 250VAC 80VDC

0

6720005351

6720005351

Weidmuller

ESX10-TC-114-DC12V-1A-E

14

9922250003

9922250003

Weidmuller

2210-T220-KOM1-H131-25A

0

9926273015

9926273015

Weidmuller

QL-T-3(13)-DM-KM-15A

0

9124363500

9124363500

Weidmuller

CIR BRKR 5.5A 250VAC 80VDC

0

SU3D50UC

SU3D50UC

Weidmuller

CB PROTECTOR 1077 3P D 50A ACDC

12

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure