Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
SU1D16UC

SU1D16UC

Weidmuller

CB PROTECTOR 1077 1P D 16A ACDC

143

9124373200

9124373200

Weidmuller

CIR BRKR THRMMAG 6A 250VAC 80VDC

0

BR3D35UC

BR3D35UC

Weidmuller

CB MCB 489 3P D 35A ACDC

20

9926251702

9926251702

Weidmuller

QY-1-13-DM-OP-02

75

9922160002

9922160002

Weidmuller

CB2210-10 16A W/O AUX 16.OA

0

SU3D63UC

SU3D63UC

Weidmuller

CB PROTECTOR 1077 3P D 63A ACDC

13

9124093500

9124093500

Weidmuller

CIR BRKR 400MA 250VAC 80VDC

0

9974431902

9974431902

Weidmuller

CBH8342-10 30A W/O AUX

0

9926241101

9926241101

Weidmuller

QZ-1-13-D-3-01

0

9912011302

9912011302

Weidmuller

CB2212-10 W/O AUX T1 0.1A

0

9124163200

9124163200

Weidmuller

CIR BRKR 3.5A 250VAC 80VDC

0

SU3C63UC

SU3C63UC

Weidmuller

CB PROTECTOR 1077 3P C 63A ACDC

21

SU1C7UC

SU1C7UC

Weidmuller

CB PROTECT 1077 277/480V C 1P 7A

159

9974331805

9974331805

Weidmuller

CBH8430-10 10A N/O AUX

0

9102003200

9102003200

Weidmuller

CIR BRKR 15A 250VAC 80VDC

0

9923150003

9923150003

Weidmuller

CIR BRKR 15A 480VAC 65VDC

0

9926252225

9926252225

Weidmuller

QL-2-13-DM-1-25

0

SU3D2UC

SU3D2UC

Weidmuller

CB PROTECTOR 1077 3P D 2A ACDC

73

SU2D1UC

SU2D1UC

Weidmuller

CB PROTECTOR 1077 2P D 1A ACDC

8

SU1C32UC

SU1C32UC

Weidmuller

CB PROTECTOR 1077 1P C 32A ACDC

214

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top