Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0119

4435.0119

Schurter

CIR BRKR THRM 6A 240VAC ROCKER

10

4435.0178

4435.0178

Schurter

CIR BRKR THRM 15A 240VAC 32VDC

7

4400.003

4400.003

Schurter

CIR BRKR THRM 10A 240VAC 48VDC

0

4400.0009

4400.0009

Schurter

CIR BRKR THRM 2.5A 240VAC 48VDC

254

4435.0345

4435.0345

Schurter

CIR BRKR THRM 8A 240VAC 60VDC

9

4420.0357

4420.0357

Schurter

CIR BRKR THRM MAG 5A 360 VDC

0

4435.0283

4435.0283

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

0

4430.3487

4430.3487

Schurter

CIR BRKR THRM 6A 240VAC 60VDC

0

4435.0315

4435.0315

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

9

4435.0123

4435.0123

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

19

TS-701-HT-3

TS-701-HT-3

Schurter

CIR BRKR THRM 3A 250VAC 50VDC

13200

4439.0006

4439.0006

Schurter

CIR BRKR THRM 240VAC 60VDC

0

4410.9020

4410.9020

Schurter

CIR BRKR THRM 15A 240VAC 28VDC

9

4430.3215

4430.3215

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

13

4430.2979

4430.2979

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

15

4430.2078

4430.2078

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

831

4435.0628

4435.0628

Schurter

CIR BRKR THRM 7A 240VAC 32VDC

17

4435.0627

4435.0627

Schurter

CIR BRKR THRM 6A 240VAC 32VDC

8

4420.0835

4420.0835

Schurter

CIR BRKR THRM MAG 20A 360 VDC

0

4430.3471

4430.3471

Schurter

CIR BRKR THRM 240VAC 60VDC

15

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure