Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4430.0523

4430.0523

Schurter

CIR BRKR THRM 11A 240VAC 60VDC

18

4430.2863

4430.2863

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

19

3-101-231

3-101-231

Schurter

CIR BRKR THRM 8A 240VAC 48VDC

88

4420.0166

4420.0166

Schurter

CIR BRKR THRM MAG 27A 277V 65V

0

4430.2105

4430.2105

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

0

4411.001

4411.001

Schurter

CIR BRKR THRM 20A 277VAC 28VDC

26

4430.2309

4430.2309

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

475

4430.1708

4430.1708

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

0

4404.0105

4404.0105

Schurter

CIRC BREAKER PCB MNT 15A

4659300

4411.0214

4411.0214

Schurter

CIR BRKR THRM 3A 277VAC 28VDC

14

4400.0323

4400.0323

Schurter

CIR BRKR THRM 800MA 240VAC 48VDC

0

4411.0007

4411.0007

Schurter

CIR BRKR THRM 15A 277VAC 28VDC

3740

4411.0018

4411.0018

Schurter

CIR BRKR THRM 16A 277VAC 28VDC

16

4435.0384

4435.0384

Schurter

CIR BRKR THRM 240VAC 60VDC

10

4435.0186

4435.0186

Schurter

CIR BRKR THRM 2A 240VAC 60VDC

0

4435.0623

4435.0623

Schurter

CIR BRKR THRM 3A 240VAC 32VDC

0

4435.0302

4435.0302

Schurter

CIR BRKR THRM 16A 240VAC 32VDC

9

4435.0174

4435.0174

Schurter

CIR BRKR THRM 10A 240VAC 32VDC

11

4420.037

4420.037

Schurter

CIR BRKR THRM MAG 1A 480V 65V

7

4404.0101

4404.0101

Schurter

CIRC BREAKER PCB MNT 8A

105

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure